{"product_id":"fresh-whole-blood-transfusion-set","title":"Fresh Whole Blood Transfusion Set","description":"\u003cdiv style=\"font-family:'Barlow',Arial,sans-serif;color:#121212;line-height:1.65;\"\u003e\n\u003cdiv style=\"background:linear-gradient(135deg,#121212 0%,#23201a 60%,#2c2719 100%);padding:34px 30px;border-radius:4px;margin:0 0 26px;\"\u003e\n\u003cdiv style=\"width:64px;height:4px;background:#9c8f61;margin:0 0 18px;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Chakra Petch',sans-serif;color:#9c8f61;font-size:13px;font-weight:700;letter-spacing:.16em;text-transform:uppercase;margin:0 0 10px;\"\u003eSafeguard Medical · Whole Blood\u003c\/div\u003e\n\u003ch3 style=\"font-family:'Chakra Petch',sans-serif;color:#f5f5f5;font-size:27px;font-weight:700;margin:0 0 12px;line-height:1.2;overflow-wrap:break-word;word-wrap:break-word;\"\u003eFresh Whole Blood Transfusion Set\u003c\/h3\u003e\n\u003cp style=\"color:#cfc8b8;font-size:15px;margin:0;max-width:640px;\"\u003eA complete sterile field transfusion set (SKU 80-801) combining the Donor Set (80-801-D) and Recipient Set (80-801-R) in one 18.5 oz package — the full walking blood bank capability, from donor screening through administration, in a single sealed pack.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#f6f4ef;border-left:4px solid #9c8f61;padding:18px 22px;margin:0 0 26px;border-radius:0 4px 4px 0;\"\u003e\n\u003cp style=\"margin:0;font-size:15px;color:#2c2719;\"\u003eThe Safeguard Medical Fresh Whole Blood Transfusion Set consolidates donor and recipient supplies into one package, eliminating the logistics of managing separate supply chains in the field. It contains the screening, collection, IV-access, filtered-administration, and documentation components to support drawing one unit of warm fresh whole blood and administering it to a hemorrhagic-shock casualty.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#23201a;border:1px solid #5e573d;border-radius:4px;padding:20px 24px;margin:0 0 28px;\"\u003e\n\u003cdiv style=\"font-family:'Chakra Petch',sans-serif;color:#9c8f61;font-size:12px;font-weight:700;letter-spacing:.16em;text-transform:uppercase;margin:0 0 8px;\"\u003eProvider-Level Device\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:14px;color:#e7e2d6;line-height:1.6;\"\u003eWhole blood collection and transfusion is an invasive procedure performed only by appropriately trained and credentialed personnel operating under a physician-directed protocol and local medical authority. This page is a product overview, not a procedural how-to or a substitute for accredited clinical training in blood typing, collection, and administration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"font-family:'Chakra Petch',sans-serif;font-size:19px;font-weight:700;color:#121212;margin:0 0 14px;padding:0 0 8px;border-bottom:2px solid #9c8f61;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;margin:0 0 30px;\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#5e573d;color:#fff;padding:9px 14px;font-weight:600;width:38%;border:1px solid #e8e4da;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;background:#fff;border:1px solid #e8e4da;\"\u003eSafeguard Medical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#5e573d;color:#fff;padding:9px 14px;font-weight:600;border:1px solid #e8e4da;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;background:#faf9f6;border:1px solid #e8e4da;\"\u003e80-801\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#5e573d;color:#fff;padding:9px 14px;font-weight:600;border:1px solid #e8e4da;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;background:#fff;border:1px solid #e8e4da;\"\u003e18.5 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#5e573d;color:#fff;padding:9px 14px;font-weight:600;border:1px solid #e8e4da;\"\u003ePackaged Dimensions\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;background:#faf9f6;border:1px solid #e8e4da;\"\u003e14.0 in. L × 10.5 in. W × 2.0 in. H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#5e573d;color:#fff;padding:9px 14px;font-weight:600;border:1px solid #e8e4da;\"\u003eIncludes\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;background:#fff;border:1px solid #e8e4da;\"\u003eComplete Donor Set + Recipient Set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#5e573d;color:#fff;padding:9px 14px;font-weight:600;border:1px solid #e8e4da;\"\u003eUsage\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;background:#faf9f6;border:1px solid #e8e4da;\"\u003eSingle-use, complete field transfusion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#5e573d;color:#fff;padding:9px 14px;font-weight:600;border:1px solid #e8e4da;\"\u003ePrimary Application\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;background:#fff;border:1px solid #e8e4da;\"\u003eFWB collection and administration; walking blood bank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#5e573d;color:#fff;padding:9px 14px;font-weight:600;border:1px solid #e8e4da;\"\u003eTCCC Context\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;background:#faf9f6;border:1px solid #e8e4da;\"\u003eDamage-control resuscitation for hemorrhagic shock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"font-family:'Chakra Petch',sans-serif;font-size:19px;font-weight:700;color:#121212;margin:0 0 14px;padding:0 0 8px;border-bottom:2px solid #9c8f61;\"\u003eCombined Kit Contents\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 10px;font-size:15px;font-weight:600;color:#5e573d;\"\u003eDonor-Side Components\u003c\/p\u003e\n\u003cul style=\"margin:0 0 20px;padding-left:22px;font-size:15px;line-height:1.7;\"\u003e\n\u003cli\u003eConstricting Band (latex-free) — 1\u003c\/li\u003e\n\u003cli\u003eGauze Sponge, 4″ × 4″ — 2\u003c\/li\u003e\n\u003cli\u003eBlood Tube, Lavender Top — 4\u003c\/li\u003e\n\u003cli\u003eBlood Tube, Red Top — 2\u003c\/li\u003e\n\u003cli\u003eBlood Collection Needle 21g × 1.25″ — 1\u003c\/li\u003e\n\u003cli\u003eSurgical Tape — 1\u003c\/li\u003e\n\u003cli\u003eClear IV Dressing — 1\u003c\/li\u003e\n\u003cli\u003eABO\/Rh Screen (EldonCard) — 1\u003c\/li\u003e\n\u003cli\u003eBlood Collection Bag — 1\u003c\/li\u003e\n\u003cli\u003eGloves (pair) — 1\u003c\/li\u003e\n\u003cli\u003eAlcohol Pads — 2\u003c\/li\u003e\n\u003cli\u003eChlorhexidine Swab — 1\u003c\/li\u003e\n\u003cli\u003e5.5″ Kelly Clamp — 1\u003c\/li\u003e\n\u003cli\u003eNylon Cord (10″) — 1\u003c\/li\u003e\n\u003cli\u003ePermanent Marker — 1\u003c\/li\u003e\n\u003cli\u003eASBP 572 Emergency Whole Blood Form — 1\u003c\/li\u003e\n\u003cli\u003eBlood Bag Label — 1\u003c\/li\u003e\n\u003cli\u003eInstructions for Use — 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin:0 0 10px;font-size:15px;font-weight:600;color:#5e573d;\"\u003eRecipient-Side Components\u003c\/p\u003e\n\u003cul style=\"margin:0 0 24px;padding-left:22px;font-size:15px;line-height:1.7;\"\u003e\n\u003cli\u003eConstricting Band (latex-free) — 1\u003c\/li\u003e\n\u003cli\u003eGauze Sponge, 4″ × 4″ — 2\u003c\/li\u003e\n\u003cli\u003eSafety IV Catheter 16g × 1.25″ — 1\u003c\/li\u003e\n\u003cli\u003eSafety IV Catheter 18g × 1.25″ — 1\u003c\/li\u003e\n\u003cli\u003eIV Set “Y”-Type with Filter — 1\u003c\/li\u003e\n\u003cli\u003eSurgical Tape — 1\u003c\/li\u003e\n\u003cli\u003eClear IV Dressing — 1\u003c\/li\u003e\n\u003cli\u003eABO\/Rh Screen (EldonCard) — 1\u003c\/li\u003e\n\u003cli\u003eGloves (pair) — 1\u003c\/li\u003e\n\u003cli\u003eAlcohol Pads — 2\u003c\/li\u003e\n\u003cli\u003eChlorhexidine Swab — 1\u003c\/li\u003e\n\u003cli\u003ePermanent Marker — 1\u003c\/li\u003e\n\u003cli\u003eSF 518 (Blood Transfusion Record) — 1\u003c\/li\u003e\n\u003cli\u003eInstructions for Use — 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"font-family:'Chakra Petch',sans-serif;font-size:19px;font-weight:700;color:#121212;margin:0 0 14px;padding:0 0 8px;border-bottom:2px solid #9c8f61;\"\u003eWhat It Is\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 16px;font-size:15px;\"\u003eCombat hemorrhage remains the leading cause of preventable battlefield death, with the majority of potentially survivable deaths attributable to uncontrolled bleeding. Fresh whole blood (FWB) transfusion administered at or near the point of injury has demonstrated survival benefit that stored component therapy cannot fully replicate — particularly in the early post-injury window when coagulopathy, acidosis, and hypothermia are most reversible.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 16px;font-size:15px;\"\u003eThis set consolidates the complete donor and recipient capability into one 18.5 oz pack: donor and recipient ABO\/Rh screening (dual EldonCards), a collection needle and bag on the donor side, large-bore 16g and 18g safety catheters and a Y-type filtered administration set on the recipient side, and documentation support via the ASBP 572 and SF 518 forms. Two EldonCards enable independent verification of donor and recipient blood type — a two-point safety check that mitigates ABO-incompatibility reaction risk in the absence of laboratory compatibility testing. Chlorhexidine swabs at both access sites reduce catheter-related infection risk during extended care.\u003c\/p\u003e\n\n\u003ch3 style=\"font-family:'Chakra Petch',sans-serif;font-size:19px;font-weight:700;color:#121212;margin:0 0 14px;padding:0 0 8px;border-bottom:2px solid #9c8f61;\"\u003eFWB vs. Component Therapy: Clinical Context\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 24px;font-size:15px;\"\u003eMilitary and civilian trauma studies have shown that warm FWB provides hemostatic resuscitation advantages over cold stored component therapy in the first hours post-injury: physiologic temperature (vs. 4°C for stored products), intact platelet function (refrigeration degrades platelet function within 24 hours), balanced coagulation factors, and reduced transfusion-related immunomodulation. The CoTCCC recognizes these advantages and positions whole blood as the preferred resuscitative product for hemorrhagic shock when available.\u003c\/p\u003e\n\n\u003cp style=\"margin:0 0 24px;font-size:15px;\"\u003e\u003ca href=\"https:\/\/www.tactical-medicine.com\/products\/fresh-whole-blood-donorset\" style=\"color:#9c8f61;text-decoration:underline;\"\u003eFresh Whole Blood Donor Set (80-801-D)\u003c\/a\u003e  |  \u003ca href=\"https:\/\/www.tactical-medicine.com\/collections\/iv-io-blood-transfusion\" style=\"color:#9c8f61;text-decoration:underline;\"\u003eIV\/IO \u0026amp; Blood Transfusion\u003c\/a\u003e  |  \u003ca href=\"https:\/\/www.tactical-medicine.com\/products\/qinflow-warrior-extreme-blood-fluid-warmer-set\" style=\"color:#9c8f61;text-decoration:underline;\"\u003eQinFlow Warrior EXTREME Warmer\u003c\/a\u003e\u003c\/p\u003e\n\n\u003c!--PPLX_USECASES_FWBT_START--\u003e\u003cdiv style=\"background:#fdf9ec;border-left:4px solid #9c8f61;padding:14px 18px;margin:0 0 28px;\"\u003e\n\u003ch3 style=\"font-family:'Chakra Petch','Barlow',sans-serif;font-size:17px;text-transform:uppercase;color:#121212;border-bottom:2px solid #9c8f61;padding-bottom:6px;margin:28px 0 12px;\"\u003eWho Uses the Fresh Whole Blood Transfusion Set (80-801)\u003c\/h3\u003e\n\u003cul style=\"margin:0 0 20px 18px;padding:0;\"\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003e\n\u003cstrong\u003eMilitary medics at Role 1 \/ Point of Injury\u003c\/strong\u003e — complete donor and recipient capability in one 18.5 oz pack for immediate FWB transfusion at the point of injury\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003e\n\u003cstrong\u003eSpecial operations medical teams (SOF medics, PJs, 18D)\u003c\/strong\u003e — single-pack logistics simplification for operators who may initiate transfusion without a second provider\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003e\n\u003cstrong\u003eWalking blood bank coordinators\u003c\/strong\u003e — both EldonCards (donor + recipient) in one package for independent two-point ABO\/Rh verification before infusion\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003e\n\u003cstrong\u003eTrauma resuscitation teams at Role 2 facilities\u003c\/strong\u003e — damage-control resuscitation with warm FWB where stored component therapy is unavailable or insufficient\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003e\n\u003cstrong\u003eCivilian trauma centers establishing FWB programs\u003c\/strong\u003e — protocol-driven FWB capability for hospitals implementing CoTCCC-aligned whole blood resuscitation doctrine\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003e\n\u003cstrong\u003eMCI \u0026amp; mass casualty response teams\u003c\/strong\u003e — rapid hemorrhagic shock resuscitation capability when blood bank product supply is exhausted or unavailable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!--PPLX_USECASES_FWBT_END--\u003e\u003c!--PPLX_COMPARISON_FWBT_START--\u003e\u003cdiv style=\"background:#fdf9ec;border-left:4px solid #9c8f61;padding:14px 18px;margin:0 0 28px;\"\u003e\n\u003ch3 style=\"font-family:'Chakra Petch','Barlow',sans-serif;font-size:17px;text-transform:uppercase;color:#121212;border-bottom:2px solid #9c8f61;padding-bottom:6px;margin:28px 0 12px;\"\u003e80-801 Complete Set vs. Buying Donor \u0026amp; Recipient Sets Separately\u003c\/h3\u003e\n\u003cul style=\"margin:0 0 20px 18px;padding:0;\"\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003e\n\u003cstrong\u003eLogistics simplification\u003c\/strong\u003e — one SKU (80-801) replaces two (80-801-D donor + 80-801-R recipient); eliminates component tracking and reduces risk of incomplete kits at point of care\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003e\n\u003cstrong\u003eCo-location guarantee\u003c\/strong\u003e — all components are vacuum-sealed together; no risk of donor and recipient components being separated during transport or storage\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003e\n\u003cstrong\u003eSolo-medic suitability\u003c\/strong\u003e — when one provider manages both donor and recipient, all-in-one configuration is operationally superior to paired separate packs\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003e\n\u003cstrong\u003eWeight comparison\u003c\/strong\u003e — combined kit is 18.5 oz; separate sets: Donor Set (80-801-D) 12.4 oz + Recipient Set (80-801-R) 6.1 oz = 18.5 oz combined — identical weight, different packaging\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003e\n\u003cstrong\u003eCost consideration\u003c\/strong\u003e — combined kit may offer marginal packaging efficiency over ordering components separately in smaller quantities\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003e\n\u003cstrong\u003eBest for\u003c\/strong\u003e — 80-801 complete set for standard walking blood bank operations; separate sets (80-801-D and 80-801-R) when roles are split between dedicated donor and recipient teams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!--PPLX_COMPARISON_FWBT_END--\u003e\u003c!--PPLX_FAQ_FRESH_WHOL_START--\u003e\u003cdiv style=\"background:#fdf9ec;border-left:4px solid #9c8f61;padding:14px 18px;margin:0 0 28px;\"\u003e\n\u003ch3 style=\"font-family:'Chakra Petch','Barlow',sans-serif;font-size:17px;text-transform:uppercase;color:#121212;border-bottom:2px solid #9c8f61;padding-bottom:6px;margin:28px 0 12px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 6px;font-weight:700;color:#121212;\"\u003eQ: How does warm fresh whole blood compare to cold stored packed red blood cells for hemorrhagic shock?\u003c\/p\u003e\n\u003cp style=\"margin:0 0 16px;\"\u003eA: Fresh whole blood provides hemostatic resuscitation advantages that packed red blood cells cannot replicate: physiologic temperature (vs. 4°C for stored products), intact platelet function (refrigeration degrades platelet function within 24-48 hours), balanced clotting factors, and reduced immunomodulation. The CoTCCC cites these advantages in positioning whole blood as the preferred resuscitative product for hemorrhagic shock when available — delivering oxygen delivery, primary hemostasis, and coagulation support in a single transfusion unit.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px;font-weight:700;color:#121212;\"\u003eQ: What is the ASBP 572 form included in the 80-801 and why is it important?\u003c\/p\u003e\n\u003cp style=\"margin:0 0 16px;\"\u003eA: The ASBP 572 Emergency Whole Blood Form is the Army Blood Program documentation form for emergency whole blood collection. Completing it with donor identity, blood type verification, collection time, and volume ensures chain-of-custody documentation that follows the blood unit through the evacuation system. This documentation is essential for post-transfusion adverse event tracking, retrospective compatibility testing from the blood tube samples collected during donation, and compliance with medical authority requirements.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px;font-weight:700;color:#121212;\"\u003eQ: Does the Fresh Whole Blood Transfusion Set include a blood filter for administration?\u003c\/p\u003e\n\u003cp style=\"margin:0 0 16px;\"\u003eA: Yes. The Recipient Set component of the 80-801 includes an IV Set Y-Type with Filter, which provides a microaggregate filter during blood administration. The filter removes clots, microaggregates, and cellular debris that may form in collected whole blood, reducing the risk of transfusion-related pulmonary complications during rapid infusion.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--PPLX_FAQ_FRESH_WHOL_END--\u003e\u003cp style=\"margin:0 0 22px;font-size:13px;color:#8f8c83;\"\u003eRelated searches: fresh whole blood transfusion set, walking blood bank kit, FWB donor recipient set, 80-801, field blood transfusion, Y-type blood administration set, EldonCard ABO screening.\u003c\/p\u003e\n\n\u003cp style=\"margin:0;padding:12px 16px;background:#f5f4f0;border-left:3px solid #9c8f61;font-size:13px;color:#555;line-height:1.5;\"\u003eAll products sourced from the actual brand manufacturer or authorized master distributors. CoTCCC recommendation status verified where applicable. Ships from MED-TAC International, Pembroke Pines, FL — clinician-founded, veteran-led, SDVOSB-certified.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Safeguard Medical","offers":[{"title":"Default Title","offer_id":42613443854454,"sku":"80-801","price":137.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0085\/6909\/4262\/files\/fresh-whole-blood-transfusion-set-6257831.jpg?v=1780705662","url":"https:\/\/tactical-medicine.com\/de\/products\/fresh-whole-blood-transfusion-set","provider":"MED-TAC International Corp.","version":"1.0","type":"link"}