{"title":"Monitoring \u0026 Diagnostics","description":"\u003cdiv class=\"mt-collection\"\u003e\n\u003cp\u003eYou can't treat what you can't measure. Pulse oximeters, blood-pressure cuffs, thermometers, glucometers, and diagnostic tools to assess a casualty, guide treatment, and \u003cstrong\u003etrend the response\u003c\/strong\u003e to it.\u003c\/p\u003e\n\u003cp\u003eMonitoring runs through the whole \u003ca href=\"\/es\/collections\/circulation\"\u003eMARCH\u003c\/a\u003e sequence — from confirming an \u003ca href=\"\/es\/collections\/airway-management\"\u003eairway\u003c\/a\u003e to catching the hypothermia in Head\/Hypothermia. Pair with \u003ca href=\"\/es\/collections\/cpr-aed\"\u003eCPR \u0026amp; AED\u003c\/a\u003e for cardiac response.\u003c\/p\u003e\n\u003c\/div\u003e","products":[{"product_id":"pulse-oximeter","title":"Oxímetro de pulso","description":"\u003cp\u003e \u003cspan\u003eOxímetro de pulso con pantalla digital, estuche de nailon y cordón\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cul\u003e\u003c\/ul\u003e","brand":"MED-TAC International","offers":[{"title":"Default Title","offer_id":39329956724854,"sku":"MEDTAC1111","price":29.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0085\/6909\/4262\/files\/pulse-oximeter-5823234.webp?v=1780705883"},{"product_id":"digital-blood-pressure-cuff","title":"Manguito de presión arterial digital","description":"\u003cp\u003e \u003cspan\u003eTensiómetro digital automático para la parte superior del brazo. Mide con precisión la presión arterial sistólica y diastólica y la frecuencia del pulso. Requiere pilas AA.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cul\u003e\u003c\/ul\u003e","brand":"MED-TAC International","offers":[{"title":"Default Title","offer_id":39329957806198,"sku":"LXBPC-UA","price":29.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0085\/6909\/4262\/products\/digital-blood-pressure-cuff-7456728.jpg?v=1780528281"},{"product_id":"cardiology-stethoscope","title":"Estetoscopio de cardiología","description":"\u003cdiv class=\"gmail_default\"\u003e El LXPCS-BK es un estetoscopio de primera calidad que cuenta con una pieza torácica de doble cabezal (adulto y pediátrico) de acero inoxidable, que incluye una campana tradicional y un diafragma. Cada lado incluye un anillo a presión que también funciona como anillo de retención del diafragma y protege al paciente del impacto de un estetoscopio frío.\u003c\/div\u003e\n\n\u003cdiv class=\"gmail_default\"\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"gmail_default\"\u003e El tubo sin látex está diseñado como \"dos tubos en uno\" para una apariencia más limpia con menos mantenimiento. Internamente, cuenta con binaurales de resorte de acero inoxidable para una mejor sensibilidad acústica.\u003c\/div\u003e\n\n\u003cdiv class=\"gmail_default\"\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"gmail_default\"\u003e Está empaquetado en una caja de regalo de espuma troquelada que incluye almohadillas adicionales para los oídos, diafragmas adicionales con estuche de piezas y un manual de instrucciones.\u003c\/div\u003e\n\n\u003cul\u003e\u003c\/ul\u003e","brand":"MED-TAC International","offers":[{"title":"Default Title","offer_id":39329959182454,"sku":"MEDTAC1114","price":19.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0085\/6909\/4262\/products\/cardiology-stethoscope-2025527.jpg?v=1780705294"},{"product_id":"manual-aneroid-sphygmomanometer","title":"Esfigmomanómetro aneroide manual","description":"\u003cp\u003e\u003cspan\u003eNuestro esfigmomanómetro aneroide está construido como el mejor y original que los profesionales médicos conocen y aman. La única diferencia es que ahora utilizamos un dial numérico calibrado en lugar de una columna de mercurio. Este estilo sigue siendo el monitor de presión arterial más confiable y más utilizado en la industria de los servicios de emergencia, pero es bastante fácil de aprender a usar en casa para cualquiera.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan\u003eNuestro manguito de presión arterial está diseñado para cumplir o superar los más altos estándares de la industria, sin tener que gastar mucho dinero. El brazalete está hecho de nailon recubierto de P\/U que es resistente al alcohol y resiste patógenos y manchas. La vejiga, el tubo y la pera están hechos de PVC y 100 % libres de látex.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan\u003eTambién se incluye con el BP Cuff una bolsa de transporte de vinilo con cremallera diseñada para proteger el medidor contra daños y hacer que todo el kit sea fácil de transportar.\u003c\/span\u003e\u003c\/p\u003e\n\n \u003cp\u003e\u003cspan\u003eEste manguito BP es una excelente adición a cualquier bolsa de EMT inicial, kit de enfermera o persona preocupada por su salud, y no solo es asequible sino que está fabricado con calidad para durar muchos años.\u003c\/span\u003e\u003c\/p\u003e","brand":"MED-TAC International","offers":[{"title":"Default Title","offer_id":39329960624246,"sku":"MEDTAC1116","price":14.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0085\/6909\/4262\/products\/manual-aneroid-sphygmomanometer-6666682.jpg?v=1780701132"},{"product_id":"mightysat-rx-fingertip-pulse-oximeter","title":"MightySat™ Rx Fingertip Pulse Oximeter — Non-Bluetooth (P\/N 42-700)","description":"\u003c!-- MightySat Rx 42-700 — non-Bluetooth configuration. MED-TAC does NOT stock Bluetooth LE variants (9809 \/ 9909 \/ 9942 \/ 9900). --\u003e\n\u003cdiv style=\"font-family:'Helvetica Neue',Arial,sans-serif;color:#121212;max-width:860px;margin:0 auto;line-height:1.65;\"\u003e\n\n  \u003c!-- Direct Answer Block --\u003e\n  \u003cdiv style=\"margin:0 0 20px;padding:16px 20px;background:#f5f4f0;border-left:4px solid #9c8f61;\"\u003e\n    \u003cp style=\"margin:0;font-size:15px;color:#121212;line-height:1.6;\"\u003eThe \u003cstrong\u003eMasimo MightySat™ Rx Fingertip Pulse Oximeter (P\/N 42-700)\u003c\/strong\u003e delivers hospital-grade SpO₂ accuracy via Masimo SET® Measure-through Motion and Low Perfusion™ technology. Measures SpO₂ (0–100%), Pulse Rate (25–240 bpm), Perfusion Index (Pi), and Pleth Variability Index (PVi®), with Signal IQ® and a rotating high-resolution color display. 73 g. Two AAA batteries, approximately 1,800 spot-checks. \u003cstrong\u003eThis is the non-Bluetooth configuration.\u003c\/strong\u003e Rx only.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Configuration Notice --\u003e\n  \u003cdiv style=\"margin:0 0 32px;padding:16px 20px;background:#121212;border-left:4px solid #9c8f61;\"\u003e\n    \u003cp style=\"margin:0 0 10px;font-size:13px;font-weight:700;color:#9c8f61;text-transform:uppercase;letter-spacing:.06em;\"\u003eConfiguration Notice — Read Before Ordering\u003c\/p\u003e\n    \u003cp style=\"margin:0 0 10px;font-size:15px;color:#f5f5f5;line-height:1.6;\"\u003ePart number \u003cstrong\u003e42-700 does not have Bluetooth.\u003c\/strong\u003e It does not pair with a phone or tablet, does not connect to the Masimo Professional Health or Masimo SafetyNet® app, and does not trend, store, export, or wirelessly share session data. All measurements are read directly off the device screen at the point of care.\u003c\/p\u003e\n    \u003cp style=\"margin:0;font-size:15px;color:#f5f5f5;line-height:1.6;\"\u003e\u003cstrong\u003eMED-TAC does not stock or order the Bluetooth LE configurations\u003c\/strong\u003e of the MightySat Rx (Masimo P\/N 9809, 9909, 9942, 9900). If wireless connectivity or app-based data capture is a requirement for your program, this is not the correct device — do not order it expecting to add that capability later. It cannot be enabled by firmware, accessory, or software.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Key Specifications Table --\u003e\n  \u003ch2 style=\"font-size:18px;font-weight:700;color:#121212;margin:0 0 12px;text-transform:uppercase;letter-spacing:.04em;\"\u003eKey Specifications\u003c\/h2\u003e\n  \u003cdiv style=\"overflow-x:auto;margin:0 0 32px;\"\u003e\n    \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth style=\"background:#121212;color:#fff;padding:10px 14px;text-align:left;font-weight:600;\"\u003eSpecification\u003c\/th\u003e\n          \u003cth style=\"background:#121212;color:#fff;padding:10px 14px;text-align:left;font-weight:600;\"\u003eDetail\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eMasimo Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003e42-700 (non-Bluetooth configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eConnectivity\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003e\u003cstrong\u003eNone — no Bluetooth, no app pairing, no wireless data export\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eTechnology\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eMasimo SET® Measure-through Motion and Low Perfusion™\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eMeasured Parameters\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eSpO₂, Pulse Rate (PR), Perfusion Index (Pi), Pleth Variability Index (PVi®)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eSpO₂ Range\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003e0–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eSpO₂ Accuracy (No Motion)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003e±2% ARMS (70–100%)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003ePulse Rate Range\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003e25–240 bpm\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eSignal Confidence\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eSignal IQ® (SIQ™) indicator beneath pleth waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eRotating, adjustable high-resolution color screen; 150° viewing angle; pleth waveform; touchpad navigation\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eSensor Interface\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eFlexible finger pad, conforms to finger to minimize external interference\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003e7.4 cm × 4.1 cm × 3.0 cm (2.9 × 1.6 × 1.2 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003e73 g (0.16 lbs) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eBattery\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eTwo 1.5V AAA batteries (approximately 1,800 spot-checks)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eIngress Protection\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eIP23\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003e5–40°C (41–104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eIncludes\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eDevice, lanyard, carry pouch, two AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003ePrescription Status\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eRx only\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Product Overview --\u003e\n  \u003ch2 style=\"font-size:18px;font-weight:700;color:#121212;margin:0 0 12px;text-transform:uppercase;letter-spacing:.04em;\"\u003eProduct Overview\u003c\/h2\u003e\n  \u003cp style=\"margin:0 0 16px;font-size:15px;\"\u003ePulse oximetry is the working vital sign for oxygenation, and the accuracy gap between a drugstore fingertip unit and the Masimo MightySat™ Rx shows up exactly where it matters: a cold, wet, hypoperfused, or moving patient. The defining technology is Masimo SET® — Signal Extraction Technology using five parallel signal processing engines to pull a reading through motion and low perfusion conditions that defeat conventional oximeters. Consumer-grade units rely on simple averaging and drop out or post a false-high number during patient movement, vasoconstriction, or poor peripheral circulation. SET® is the same signal architecture deployed in ICU and OR bedside monitors, packaged into a 73-gram fingertip device that lives in a med ruck or a kit pocket.\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 16px;font-size:15px;\"\u003eBeyond SpO₂ and pulse rate, this configuration measures two additional parameters with real clinical utility. Perfusion Index (Pi) quantifies the ratio of pulsatile to non-pulsatile blood flow at the sensor site — a direct read on peripheral perfusion that tracks with vasoconstriction, shock state, and vasoactive medication effect. Pleth Variability Index (PVi®) measures respiratory-cycle variation in the plethysmographic signal and is used clinically as an index of fluid responsiveness. Signal IQ® sits under the pleth waveform and gives the provider a confidence indicator on the displayed value — a reading with poor signal quality is flagged as such rather than presented as clinical truth.\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 16px;font-size:15px;\"\u003eThe rotating, adjustable high-resolution display with 150° viewing angle solves the practical problem of reading a fixed-orientation screen when the patient's hand is where it is, not where you want it — during extrication, transport, or an exam in a confined space. The flexible finger pad conforms to the digit and reduces external light and motion interference. Two AAA batteries deliver roughly 1,800 spot-checks and are field-replaceable with commodity cells, with no charging cradle, proprietary pack, or cable to lose.\u003c\/p\u003e\n\n  \u003c!-- Why non-Bluetooth --\u003e\n  \u003ch2 style=\"font-size:18px;font-weight:700;color:#121212;margin:0 0 12px;text-transform:uppercase;letter-spacing:.04em;\"\u003eWhy the Non-Bluetooth Configuration\u003c\/h2\u003e\n  \u003cp style=\"margin:0 0 16px;font-size:15px;\"\u003eFor most tactical, EMS, fire, and agency spot-check applications, the absence of a radio is a feature rather than a limitation. There is no wireless emission to manage, no pairing step under time pressure, no app dependency, no phone battery in the critical path, and no device that has to clear an agency IT or information-security review before it can be fielded. Departments operating under restricted-electronics policies, and units working in RF-disciplined environments, routinely specify the non-connected configuration for exactly these reasons. The clinical measurement is identical — Bluetooth changes what happens to the number after you read it, not the number itself.\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 28px;font-size:15px;\"\u003eThe tradeoff is real and should be understood before purchase: without Bluetooth there is no automatic trending, no session history export, no CSV download, and no telehealth data sharing. Documentation is manual — the provider reads the display and records the value. If your program requires automated capture into a patient care report or a remote monitoring workflow, specify a connected device instead. MED-TAC does not carry the Bluetooth-equipped MightySat Rx configurations.\u003c\/p\u003e\n\n  \u003c!-- Internal Links --\u003e\n  \u003cp style=\"margin:0 0 32px;font-size:15px;\"\u003eSee also: \u003ca href=\"https:\/\/www.tactical-medicine.com\/collections\/diagnostic-monitoring\" style=\"color:#9c8f61;text-decoration:underline;\"\u003eDiagnostic \u0026amp; Monitoring Equipment\u003c\/a\u003e | \u003ca href=\"https:\/\/www.tactical-medicine.com\/collections\/ifak-kits-first-aid\" style=\"color:#9c8f61;text-decoration:underline;\"\u003eIFAK Kits \u0026amp; First Aid\u003c\/a\u003e\u003c\/p\u003e\n\n  \u003c!-- Compliance Footer --\u003e\n  \u003cp style=\"margin:24px 0 0;padding:12px 16px;background:#f5f4f0;border-left:3px solid #9c8f61;font-size:13px;color:#555;line-height:1.5;\"\u003eRx only. Federal law restricts this device to sale by or on the order of a licensed practitioner. All products sourced from the actual brand manufacturer or authorized master distributors. Ships from MED-TAC International — clinician-founded, veteran-led, SDVOSB-certified. South Florida, US of A.\u003c\/p\u003e\n\n\u003c\/div\u003e\n","brand":"Masimo","offers":[{"title":"Default Title","offer_id":40031581241462,"sku":"42-700","price":399.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0085\/6909\/4262\/products\/mightysat-rx-fingertip-pulse-oximeter-3270189.jpg?v=1780705552"},{"product_id":"capnospot-pneumothorax-decompression-indicator","title":"Capnospot Pneumothorax Decompression Indicator","description":"\u003c!-- Capnospot Pneumothorax Decompression Indicator — GEO-optimized product description --\u003e\n\u003cdiv style=\"font-family:'Helvetica Neue',Arial,sans-serif;color:#121212;max-width:860px;margin:0 auto;line-height:1.65;\"\u003e\n\n  \u003c!-- Direct Answer Block --\u003e\n  \u003cdiv style=\"margin:0 0 28px;padding:16px 20px;background:#f5f4f0;border-left:4px solid #9c8f61;\"\u003e\n    \u003cp style=\"margin:0;font-size:15px;color:#121212;line-height:1.6;\"\u003eThe Pneumeric Capnospot® is a novel colorimetric CO₂ detection device that attaches to any commercially available needle decompression catheter via standard Luer fitting to provide objective, visual confirmation of successful pleural entry within seconds. When the needle enters the pneumothorax space, CO₂-rich air produces a clear color change from blue to yellow — replacing the subjective \"gush of air\" assessment that fails in up to 50% of cases in trained professionals. Winner of the 2023 EMS World Expo Innovation Award.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Key Specifications Table --\u003e\n  \u003ch2 style=\"font-size:18px;font-weight:700;color:#121212;margin:0 0 12px;text-transform:uppercase;letter-spacing:.04em;\"\u003eKey Specifications\u003c\/h2\u003e\n  \u003cdiv style=\"overflow-x:auto;margin:0 0 32px;\"\u003e\n    \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth style=\"background:#121212;color:#fff;padding:10px 14px;text-align:left;font-weight:600;\"\u003eSpecification\u003c\/th\u003e\n          \u003cth style=\"background:#121212;color:#fff;padding:10px 14px;text-align:left;font-weight:600;\"\u003eDetail\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003ePneumeric Medical\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eDevice Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eColorimetric CO₂ Detection Indicator (Visual Carbon Dioxide Detection Device)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eMechanism\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eColorimetric capnography — color changes blue → yellow in presence of CO₂\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eConfirmation Speed\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003e\u0026lt;5 seconds from pleural entry\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eConnection Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eStandard Luer fitting — compatible with all commercially available decompression needles and catheters\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eCompatible Devices\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eNAR ARS® (10 Ga. \u0026amp; 14 Ga.), NAR Enhanced ARS®, NAR SPEAR®, and any Luer-compatible catheter\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003e3.2 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eSmall, lightweight, portable; functions in low-light conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eFDA Statement\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003e\"Used for more accurate placement of pneumothorax decompression devices than the current standard of care auditory assessments\" (FDA)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eAward\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003e2023 EMS World Expo Innovation Award Winner\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eImportant Note\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eNeedle\/catheter NOT included — attach to your existing decompression device\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Product Overview --\u003e\n  \u003ch2 style=\"font-size:18px;font-weight:700;color:#121212;margin:0 0 12px;text-transform:uppercase;letter-spacing:.04em;\"\u003eProduct Overview\u003c\/h2\u003e\n  \u003cp style=\"margin:0 0 16px;font-size:15px;\"\u003eThe standard of care for confirming successful needle thoracostomy has historically been auditory: providers listen for a \"rush\" or \"hiss\" of air as the needle enters the pleural space. This method is subjective, highly susceptible to environmental noise (helicopters, gunfire, sirens, crowd noise), and dependent on a tension large enough to produce audible flow. Research has consistently documented a 20–50% failure rate for needle decompression in well-trained professionals — a failure rate that contributes directly to preventable mortality. Data shows that successful therapy reduces 24-hour mortality by approximately 25%.\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 16px;font-size:15px;\"\u003eThe Capnospot transforms this ambiguous, high-stakes assessment into an unambiguous binary result: the device turns from blue to yellow when carbon dioxide — which is elevated in the tension pneumothorax space compared to atmospheric air — contacts the colorimetric indicator. The color change occurs within 5 seconds of pleural entry, providing the fastest objective confirmation currently available at the point of injury. If the catheter loses patency or migrates out of the pleural space, the Capnospot reverts to its original blue color — alerting the provider immediately to reposition or replace the catheter.\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 16px;font-size:15px;\"\u003eThe science behind this approach is well-established: the gaseous composition of a tension pneumothorax has an elevated partial pressure of CO₂ relative to normal atmospheric air, making colorimetric capnography an ideal confirmation test. The device was initially designed and developed at a leading healthcare organization, and current clinical data demonstrates higher confirmation accuracy than clinical judgment alone — a finding recognized by the FDA, which states the Capnospot is \"used for more accurate placement of pneumothorax decompression devices than the current standard of care auditory assessments.\"\u003c\/p\u003e\n\n  \u003c!-- Why Objective Confirmation Matters --\u003e\n  \u003ch2 style=\"font-size:18px;font-weight:700;color:#121212;margin:0 0 12px;text-transform:uppercase;letter-spacing:.04em;\"\u003eThe Problem with Auditory Confirmation\u003c\/h2\u003e\n  \u003cdiv style=\"overflow-x:auto;margin:0 0 32px;\"\u003e\n    \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth style=\"background:#121212;color:#fff;padding:10px 14px;text-align:left;font-weight:600;\"\u003eLimitation\u003c\/th\u003e\n          \u003cth style=\"background:#121212;color:#fff;padding:10px 14px;text-align:left;font-weight:600;\"\u003eAuditory (\"Hiss\") Method\u003c\/th\u003e\n          \u003cth style=\"background:#121212;color:#fff;padding:10px 14px;text-align:left;font-weight:600;\"\u003eCapnospot CO₂ Method\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eNoise environment\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eSeverely degraded by helicopter, gunfire, crowds\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eUnaffected — visual, not auditory\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eSubjectivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eHigh — depends on operator perception\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eNone — objective color change (blue → yellow)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eMissed catheter loss\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eNot detected\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eCapnospot reverts to blue — immediate alert\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eLow-light use\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eAuditory only — unaffected\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eReadable in low-light conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eConfirmation speed\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eImmediate if tension is large enough\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003e\u0026lt;5 seconds — even for smaller tension volumes\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eEvidence base\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eLong-standing clinical practice\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eClinical data; FDA-recognized accuracy improvement; 2023 EMS World Expo Innovation Award\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- How to Use --\u003e\n  \u003ch2 style=\"font-size:18px;font-weight:700;color:#121212;margin:0 0 12px;text-transform:uppercase;letter-spacing:.04em;\"\u003eHow to Use the Capnospot\u003c\/h2\u003e\n  \u003col style=\"margin:0 0 24px;padding-left:20px;font-size:15px;line-height:1.8;\"\u003e\n    \u003cli\u003eAttach the Capnospot to the distal (hub) end of your decompression needle or catheter via standard Luer connection prior to insertion\u003c\/li\u003e\n    \u003cli\u003ePerform needle decompression per TCCC protocol (perpendicular to chest wall, to the hub)\u003c\/li\u003e\n    \u003cli\u003eObserve the indicator: color change from blue → yellow within 5 seconds confirms pleural entry and successful decompression\u003c\/li\u003e\n    \u003cli\u003eIf the indicator remains blue, the needle has not entered the pleural space — reposition or attempt at the alternate site with a new needle\/catheter unit\u003c\/li\u003e\n    \u003cli\u003eMonitor during dwell: if the indicator reverts to blue after initial yellow confirmation, catheter patency may be lost — reassess and reposition\u003c\/li\u003e\n  \u003c\/ol\u003e\n\n  \u003c!-- Clinical Data Summary --\u003e\n  \u003ch2 style=\"font-size:18px;font-weight:700;color:#121212;margin:0 0 12px;text-transform:uppercase;letter-spacing:.04em;\"\u003eClinical Data Summary\u003c\/h2\u003e\n  \u003cul style=\"margin:0 0 24px;padding-left:20px;font-size:15px;line-height:1.8;\"\u003e\n    \u003cli\u003eTension pneumothorax: 100% fatality if untreated — among the most time-critical reversible trauma emergencies\u003c\/li\u003e\n    \u003cli\u003eNeedle thoracostomy failure rate: 20–50% in well-trained professionals (published literature)\u003c\/li\u003e\n    \u003cli\u003eSuccessful therapy: associated with approximately 25% reduction in 24-hour mortality\u003c\/li\u003e\n    \u003cli\u003eCapnospot confirmation speed: \u0026lt;5 seconds from pleural entry\u003c\/li\u003e\n    \u003cli\u003eRecognition: Winner, 2023 EMS World Expo Innovation Award; FDA-recognized accuracy improvement over auditory assessment\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003c!-- Related Products --\u003e\n  \u003cp style=\"margin:0 0 32px;font-size:15px;\"\u003ePair the Capnospot with the \u003ca href=\"https:\/\/www.tactical-medicine.com\/collections\/chest-thoracic-supplies\" style=\"color:#9c8f61;text-decoration:underline;\"\u003eNAR ARS® or SPEAR® needle decompression devices\u003c\/a\u003e for a complete, objective needle thoracostomy system. Browse the full \u003ca href=\"https:\/\/www.tactical-medicine.com\/collections\/chest-thoracic-supplies\" style=\"color:#9c8f61;text-decoration:underline;\"\u003eChest \u0026amp; Thoracic Supplies\u003c\/a\u003e collection or explore \u003ca href=\"https:\/\/www.tactical-medicine.com\/collections\/respiratory-support\" style=\"color:#9c8f61;text-decoration:underline;\"\u003eRespiratory Support\u003c\/a\u003e products.\u003c\/p\u003e\n\n  \u003c!-- Compliance Footer --\u003e\n  \u003cp style=\"margin:24px 0 0;padding:12px 16px;background:#f5f4f0;border-left:3px solid #9c8f61;font-size:13px;color:#555;line-height:1.5;\"\u003eAll products sourced from the actual brand manufacturer or authorized master distributors. CoTCCC recommendation status verified where applicable. Ships from MED-TAC International, Pembroke Pines, FL — clinician-founded, veteran-led, SDVOSB-certified.\u003c\/p\u003e\n\n\u003c\/div\u003e\n","brand":"Pneumeric","offers":[{"title":"Default Title","offer_id":40174670151798,"sku":null,"price":32.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0085\/6909\/4262\/products\/capnospot-pneumothorax-decompression-indicator-9945838.jpg?v=1763154877"},{"product_id":"disposable-virus-sampling-tube","title":"Nasal Swab - Virus Sampling Kit (Nasopharyngeal)","description":"\u003c!-- Nasal Swab - Virus Sampling Kit (Nasopharyngeal) — GEO-optimized product description --\u003e\n\u003cdiv style=\"font-family:'Helvetica Neue',Arial,sans-serif;color:#121212;max-width:860px;margin:0 auto;line-height:1.65;\"\u003e\n\n  \u003c!-- Direct Answer Block --\u003e\n  \u003cdiv style=\"margin:0 0 28px;padding:16px 20px;background:#f5f4f0;border-left:4px solid #9c8f61;\"\u003e\n    \u003cp style=\"margin:0;font-size:15px;color:#121212;line-height:1.6;\"\u003eThe Nasal Swab Virus Sampling Kit (Nasopharyngeal) (SKU: covid-test-fb-nasal) is a customer-ready, pre-packaged clinical specimen collection kit used for the collection and transport of nasopharyngeal specimens to testing laboratories. Each kit contains a labeled 3 mL screw-cap tube of viral transport medium and one or two nasopharyngeal swabs in a peel pouch — designed for single-patient use in clinical, occupational, and field testing environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Key Specifications Table --\u003e\n  \u003ch2 style=\"font-size:18px;font-weight:700;color:#121212;margin:0 0 12px;text-transform:uppercase;letter-spacing:.04em;\"\u003eKey Specifications\u003c\/h2\u003e\n  \u003cdiv style=\"overflow-x:auto;margin:0 0 32px;\"\u003e\n    \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth style=\"background:#121212;color:#fff;padding:10px 14px;text-align:left;font-weight:600;\"\u003eSpecification\u003c\/th\u003e\n          \u003cth style=\"background:#121212;color:#fff;padding:10px 14px;text-align:left;font-weight:600;\"\u003eDetail\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eVendor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eMEDTECH Resource\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003ecovid-test-fb-nasal\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003e0.5 lb per kit\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eTransport Medium\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003e3 mL labeled screw-cap tube, non-propagating viral transport medium\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eSwab Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eNasopharyngeal swab(s) in sterile peel pouch\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003ePackaging\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eCustomer-ready, pre-packaged per kit\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eIntended Use\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#fff;\"\u003eCollection and transport of clinical specimens for viral laboratory testing\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eBulk Orders\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e4da;background:#faf9f6;\"\u003eAvailable — call 1-800-693-0032 for bulk pricing\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Product Overview --\u003e\n  \u003ch2 style=\"font-size:18px;font-weight:700;color:#121212;margin:0 0 12px;text-transform:uppercase;letter-spacing:.04em;\"\u003eProduct Overview\u003c\/h2\u003e\n  \u003cp style=\"margin:0 0 16px;font-size:15px;\"\u003eThe Nasal Swab Virus Sampling Kit is a complete, single-use clinical specimen collection system for nasopharyngeal specimen collection and transport to a certified testing laboratory. The kit is pre-packaged and customer-ready, meaning no additional assembly is required — each kit arrives with all components needed to perform a single collection and transport safely and within chain-of-custody requirements.\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 16px;font-size:15px;\"\u003eThe 3 mL labeled screw-cap tube contains non-propagating viral transport medium — a buffered solution designed to preserve viral viability during transport from the collection site to the laboratory, without allowing viral replication that could compromise specimen integrity. The labeled tube format supports documentation and chain-of-custody tracking.\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 16px;font-size:15px;\"\u003eThese kits are suitable for clinical screening operations, occupational health programs, public health surveillance, and any setting where reliable viral specimen collection from a nasopharyngeal swab is required. Bulk orders for institutional and governmental purchasing are available by calling 1-800-693-0032.\u003c\/p\u003e\n\n  \u003c!-- Internal Links --\u003e\n  \u003cp style=\"margin:0 0 32px;font-size:15px;\"\u003eSee also: \u003ca href=\"https:\/\/www.tactical-medicine.com\/collections\/ifak-kits-first-aid\" style=\"color:#9c8f61;text-decoration:underline;\"\u003eIFAK Kits \u0026amp; First Aid\u003c\/a\u003e | \u003ca href=\"https:\/\/www.tactical-medicine.com\/collections\/bandages-dressings\" style=\"color:#9c8f61;text-decoration:underline;\"\u003eBandages \u0026amp; Dressings\u003c\/a\u003e\u003c\/p\u003e\n\n  \u003c!-- Compliance Footer --\u003e\n  \u003cp style=\"margin:24px 0 0;padding:12px 16px;background:#f5f4f0;border-left:3px solid #9c8f61;font-size:13px;color:#555;line-height:1.5;\"\u003eAll products sourced from the actual brand manufacturer or authorized master distributors. CoTCCC recommendation status verified where applicable. Ships from MED-TAC International, Pembroke Pines, FL — clinician-founded, veteran-led, SDVOSB-certified.\u003c\/p\u003e\n\n\u003c\/div\u003e\n","brand":"MEDTECH Resource","offers":[{"title":"Default Title","offer_id":41668385013878,"sku":"covid-test-fb-nasal","price":14.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0085\/6909\/4262\/files\/nasal-swab-virus-sampling-kit-nasopharyngeal-1818401.jpg?v=1780530801"}],"url":"https:\/\/tactical-medicine.com\/es\/collections\/monitoring-diagnostics\/tier:basic+capability:diagnostic+config:item+config:kit.oembed","provider":"MED-TAC International Corp.","version":"1.0","type":"link"}