How long will a Size D oxygen cylinder last?
Usable duration depends on your actual regulator gauge pressure, prescribed flow rate, and safe residual reserve rather than nominal tank volume alone. While a Size D cylinder has an approximate nominal capacity of 14.6 cubic feet (~415 liters) at full rated service pressure, prehospital planning calculates usable minutes from the gauge reading using a 200 psi safe residual reserve and the standard 0.16 L/psi D-cylinder planning factor: Minutes = (gauge psi − 200) × 0.16 ÷ flow rate (L/min), rounded down. Using that formula at an example 2,000 psi gauge reading (288 L usable after a 200 psi reserve), estimated runtimes are approximately 19 minutes at 15 L/min, 28 minutes at 10 L/min, 48 minutes at 6 L/min, 72 minutes at 4 L/min, and 144 minutes at 2 L/min. Always verify cylinder pressure on the regulator gauge before patient use and refer to the D Cylinder Oxygen Duration Chart on this page for calculation assumptions and additional example gauge readings.
Does the Size D Oxygen Cylinder come filled?
The MED-TAC Size D Oxygen Cylinder ships empty and must be filled with medical-grade oxygen by an authorized medical gas supplier in your area before clinical use. This is standard for oxygen cylinder sales due to shipping regulations for compressed gases. After receiving the cylinder, contact your local medical gas supplier or medical gas distributor to have it filled. Cylinder fill cost and availability vary by location.
What regulator do I need for this cylinder?
The Size D Oxygen Cylinder uses a CGA870 post valve — the U.S. standard for portable medical oxygen cylinders. It requires a CGA870-compatible oxygen regulator, sold separately. The MED-TAC Mini O2 Regulator (MEDTAC1110) is compatible and provides 0–15 LPM adjustable constant flow. The cylinder wrench included with the regulator is used to open and close the cylinder valve.
Can I use this cylinder with a non-rebreather mask and a BVM?
Yes. When paired with a compatible CGA870 regulator (sold separately) set to 10–15 L/min, the Size D cylinder can supply oxygen to a non-rebreather mask for spontaneously breathing patients or to a bag-valve mask (BVM) reservoir bag inlet for patients requiring assisted ventilation. Because high-flow delivery (10–15 L/min) depletes portable cylinders quickly, always calculate usable runtime from your current gauge pressure, prescribed flow rate, and a 200 psi safe residual reserve before departure rather than relying on nominal capacity. Using the D Cylinder Oxygen Duration Chart on this page (0.16 L/psi factor with a 200 psi reserve), an example 2,000 psi gauge reading provides approximately 19 minutes at 15 L/min or 28 minutes at 10 L/min. Stage spare cylinders or larger onboard oxygen supplies according to expected transport duration, patient demand, and agency medical direction.
What are the safety requirements for storing and transporting a medical oxygen cylinder?
Oxygen cylinders must be stored upright and secured against falling, in a well-ventilated area away from heat sources, sparks, and open flames. Do not store in enclosed vehicle compartments for extended periods without ventilation. During transport, cylinders must be secured in a cylinder holder or bracket to prevent rolling or impact. Follow CGA (Compressed Gas Association) and DOT regulations for compressed medical gas handling. Never use oil or grease on oxygen fittings. Inspect cylinders regularly for damage, corrosion, or valve defects.