0
Free US Shipping $200+  •  APO/FPO Always Ships Free Shop All →
Free US Shipping $200+ • APO/FPO Always Free ★ SDVOSB • CAGE: 9VFL3 • Medical SME-Led

ChitoGauze® XR PRO Hemostatic Gauze

(4 reviews)
$46.34
Request a custom quote for bulk orders, agency procurement, or government purchases
FREE APO/FPO SHIPPING • EVERY ORDER • NO MINIMUM

Guaranteed duty-free priority delivery to all deployed military postal codes worldwide.

Ships from Florida HQ Free Shipping $200+ CONUS Free APO/FPO Shipping 30-Day Unopened Returns
Fulfillment Timeline: In stock merchandise ships within 48-72 hours from Florida HQ.
$46.34
PRODUCT INFORMATION
HemCon® by Tricol Biomedical · Hemostatic Packing Gauze
ChitoGauze® XR PRO Hemostatic Gauze
A 3 in. × 4 yd Z-folded nonwoven gauze coated with chitosan, with a radiopaque thread built in — XR stands for X-ray detectable. The TCCC Guidelines name ChitoGauze as an alternative to Combat Gauze for bleeding a tourniquet cannot reach, and this item, Tricol 1090, carries the NSN on the Evidence-Based Standard Devices & Adjuncts list.
evidence-based standardNSN 6510-01-591-77403 in. × 4 yd Z-foldX-ray detectable — 1 threadFDA 510(k) cleared

Twelve feet of chitosan-coated gauze that packs like plain gauze, carries the NSN on the evidence-based list, and shows up on the surgeon's X-ray.

The short answer
What it is
Chitosan-coated hemostatic packing gauze, 3 in. × 4 yd, with one radiopaque thread — one sterile dressing per sealed foil pouch.
Use it for
Life-threatening bleeding from a wound you can pack — the groin and armpit, the neck, and deep limb wounds a tourniquet cannot control.
Hold pressure
Tricol's instructions call for pressure until the bleeding is controlled; the TCCC Guidelines set at least 3 minutes for any hemostatic dressing. Both apply: hold at least 3 minutes, and keep holding until the bleeding has stopped and the packing is secured.
Who carries it
Military medics, law enforcement, EMS and trained civilian responders. Tricol labels it for use by trained emergency responders.

At a glance

Active agent
Chitosan coating
Gauze
3 in. × 4 yd (7.6 cm × 3.7 m)
Format
Z-fold, sealed foil pouch
X-ray detectable
Yes — 1 radiopaque thread
Pressure hold
Until bleeding is controlled; at least 3 min (TCCC)
Storage
11–26 °C (52–78 °F), dry
Weight
0.7 oz (20 g)
NSN
6510-01-591-7740
Manufacturer item
Tricol 1090
FDA
510(k) K102546

12 things to know about ChitoGauze XR PRO

What the XR means, where it sits in TCCC, and what the human and animal studies actually found.

  1. 01

    XR means X-ray detectable

    A radiopaque thread is built into the gauze so a packed dressing shows on an X-ray. FDA cleared the X-ray version of ChitoGauze in 2010; in testing to ASTM F640, its radiopacity matched the standard aluminum reference.3,5 Tell the receiving team it is there.

  2. 02

    This is the ChitoGauze on the evidence-based list

    The Evidence-Based Standard Devices & Adjuncts list carries ChitoGauze under NSN 6510-01-591-77402 — the NSN Tricol assigns to this item, XR PRO 1090.4 The TCCC Guidelines name ChitoGauze an alternative hemostatic adjunct; Combat Gauze is the evidence-based hemostatic dressing of choice.1 ChitoGauze was added in Guidelines Change 13-05, after a review found chitosan gauze at least as effective as Combat Gauze in animal studies.9

  3. 03

    How chitosan stops bleeding

    Chitosan carries a positive charge and red blood cells a negative one. Tricol describes the coated gauze drawing red cells to it and forming a tight, adherent seal over the source — a process it states runs separately from the body's own clotting cascade.4

  4. 04

    Coated gauze — nothing to pour, no heat

    ChitoGauze is a polyester/rayon blend nonwoven medical gauze coated with chitosan, Z-folded and sealed in a foil pouch.5 It contains no powder or granules and generates no heat.8

  5. 05

    Hold until the bleeding stops — and at least 3 minutes

    Tricol's instructions: apply pressure until bleeding is controlled.3 The TCCC Guidelines: at least 3 minutes of direct pressure for any hemostatic dressing.1 The two do not compete. Hold for at least 3 minutes, and keep holding as long as the wound is still bleeding.

  6. 06

    You can cut it — keep the thread

    If you cut the dressing to a smaller size, make sure the radiopaque thread is in the piece you pack. Discard any unused portion.3

  7. 07

    Four yards, and more than one if needed

    The strip is 3 in. wide and 144 in. long.2 Use enough to fill the wound and contact every bleeding surface; a large cavity may take more than one dressing.3

  8. 08

    FDA-cleared for severely bleeding wounds

    Cleared under 510(k) K102546 on 17 November 2010 as a hemostatic dressing for the external, temporary control of severely bleeding wounds, and gamma-sterilized to a sterility assurance level of 10⁻⁶.5 Tricol labels it for use by trained emergency responders.3

  9. 09

    66 real patients in Dutch EMS

    Two Dutch ambulance services carried ChitoGauze from 2012 to 2014 and used it when gauze and pressure failed or were unlikely to work. Bleeding stopped in 46 of 66 patients and slowed in 13; it failed in 7, with user error a factor in 3. No side effects were reported.10

  10. 10

    The animal evidence is mixed — read all of it

    In standard swine femoral-artery models, ChitoGauze performed as well as Combat Gauze, with no statistically significant differences.12,13 In coagulopathic swine, survival with XR PRO was 71% against 86% for Combat Gauze, seven animals per group,11 and in a 24-hour prolonged-field-care model ChitoGauze did not meet the study's 2-hour survival threshold.14 A 24-hour safety study found embolic material in the pulmonary circulation with ChitoGauze PRO, Combat Gauze and Celox Gauze alike.15

  11. 11

    Made from shellfish — allergy is rarely the issue

    ChitoGauze contains chitosan from shellfish.3 Shellfish allergy is a reaction to shellfish protein; Tricol states its chitosan process removes residual shrimp protein,4 and volunteers with documented shellfish allergy tolerated a HemCon chitosan bandage without reaction.16 In a life-threatening bleed, a reported shellfish allergy is not a reason to withhold it — watch for redness, swelling or other signs of a reaction.3

  12. 12

    Store it between 52 and 78 °F

    Tricol labels storage at 11–26 °C (52–78 °F), kept dry.3,6 A summer vehicle or a sun-baked aid bag can run hotter than that, so keep kits out of the heat. Do not use a dressing whose seal is broken or whose contents are wet.3

How to pack ChitoGauze XR PRO

Tricol's instructions, in the packing order taught in TCCC, TECC and public bleeding-control courses.

  1. 1
    Find the source. Expose the wound and find where the blood is actually coming from. Keep direct pressure on it with your hand while you open the foil pouch.
  2. 2
    Start with a tight wad. Make the first folds into a firm ball — the "power ball" — cover the bleeding source with it and press directly onto it with your fingers.3
  3. 3
    Feed it in. Work the gauze in one or two folds at a time, keeping pressure on what is already packed.
  4. 4
    Fill every corner. Pack the gauze completely into the wound track until it fills the wound and touches every bleeding surface. Use a second dressing if the first is not enough.3
  5. 5
    Cutting it? Keep the thread. If you cut the dressing smaller, the radiopaque thread must be in the piece you pack.3
  6. 6
    Hold firm pressure. At least 3 minutes per the TCCC Guidelines, and until the bleeding is controlled per Tricol's instructions1,3 — whichever is longer.
  7. 7
    Lock it in. Wrap and secure the dressing with a pressure bandage to keep pressure on the wound.3
  8. 8
    If it keeps bleeding, repack. Remove the packing and pack again with a fresh dressing, the same type or another hemostatic.1 Piling more gauze on top of a failed pack does not fix it.
  9. 9
    Hand it off. Tell the receiving team a chitosan hemostatic with an X-ray thread is in the wound, give them the pouch, and keep reassessing.
Train before you need it. Wound packing is a hands-on skill. Practice on a wound-packing trainer with inert training gauze and keep your live dressing sealed for the casualty.

Where it fits

Use it for
  • Junctional wounds — groin and armpit — where a limb tourniquet cannot be applied
  • Neck wounds, packed with care so the airway is not compressed; the lower neck above the collarbone can be packed
  • Deep limb wounds where a tourniquet is not possible, or as an adjunct when a trained provider converts a tourniquet1
  • Any deep, packable wound with life-threatening external bleeding5
Not for
  • The chest or abdomen — never pack into the chest or abdominal cavity
  • Life-threatening limb bleeding a tourniquet can control — tourniquet first1
  • Over the eyes, or near the spine3
  • Implanting — it is for external, temporary use only3
  • Practice — train with inert trainers, not live dressings

The evidence

Every study cited above, the product it tested, and how strong the evidence is.

Study Evidence type What was studied What it found
Te Grotenhuis et al., Injury 2016 Human · prospective series HemCon ChitoGauze in 66 patients, two Dutch EMS services, 2012–2014, used when gauze and pressure failed or were unlikely to work Bleeding stopped in 46, reduced in 13, failed in 7 (user error in 3); no side effects reported
Gerling et al., J Trauma Acute Care Surg 2023 Animal · randomized ChitoGauze XR Pro vs Combat Gauze and six other agents, coagulopathic swine, junctional arterial injury, 7 per group Survival 71% vs 86% Combat Gauze; blood loss 554 ± 613 mL vs 260 ± 319 mL; authors judged most agents comparable to Combat Gauze
Rall et al., J Trauma Acute Care Surg 2013 Animal · randomized HemCon ChitoGauze vs Combat Gauze and three other dressings, swine femoral artery injury, 3-minute hold Survival 70% vs 60% and immediate hemostasis 60% vs 30%; differences not statistically significant
Schwartz et al., Prehosp Emerg Care 2011 Animal · comparative ChitoGauze vs Combat Gauze, 6 mm femoral artery punch, 14 swine, 2-minute hold No statistically significant differences; trends favored ChitoGauze; no retained material on histology
Booms et al., Mil Med 2026 Animal · pilot ChitoGauze and five other dressings, swine junctional wound, followed up to 24 hours ChitoGauze did not meet the 2-hour survival threshold; Combat Gauze, Celox Gauze, Celox Rapid and Veriset did
Otrocka-Domagała et al., Pol J Vet Sci 2016 Animal · safety ChitoGauze PRO, Combat Gauze and Celox Gauze left 24 hours in transected femoral artery wounds, 9 swine Embolic material in the pulmonary circulation; authors judged all three unsuitable for long-term application
Bennett et al., J Spec Oper Med 2014 Expert review · guideline change Review of chitosan gauze dressings for TCCC Guidelines Change 13-05 Chitosan gauze at least as effective as Combat Gauze in animal studies; ChitoGauze and Celox Gauze added to TCCC
Waibel et al., Mil Med 2011 Human · safety challenge HemCon chitosan bandage applied to volunteers with documented shellfish allergy All subjects tolerated the bandage without reaction

Strongest to weakest: human studies, then animal studies, then expert review. The Dutch series is real patients without a comparison group; the swine results depend on the injury model, the hold time and whether the animals were coagulopathic.

How it compares

The packing options a buyer most often weighs against ChitoGauze XR PRO.

ChitoGauze XR PRO ChitoGauze XR2 PRO Combat Gauze Celox Rapid
Active agent Chitosan coating on nonwoven gauze Chitosan coating on nonwoven gauze Kaolin (mineral) Chito-R™ chitosan granules bonded to gauze
How it stops bleeding Positively charged chitosan draws red cells into an adherent seal (manufacturer) Same gauze as XR PRO Speeds the body's own clotting cascade Forms an adhesive gel that binds blood cells
Strip 3 in. × 4 yd (12 ft) Z-fold 3 in. × 4 yd (12 ft) Z-fold 3 in. × 4 yd (12 ft) Z-fold 3 in. × 5 ft Z-fold
X-ray detectable Yes — 1 thread Yes — 2 threads Yes — radiopaque strip Yes — radiopaque thread
Labeled pressure hold Until bleeding is controlled Until bleeding is controlled At least 3 min 60 s, or until bleeding stops
evidence-based standard Yes — carries the evidence-based-listed NSN Yes Yes — hemostatic dressing of choice Yes
Shellfish-derived Yes Yes No Yes

Labeled hold times come from each manufacturer's instructions; the TCCC Guidelines set at least 3 minutes of direct pressure for any hemostatic dressing.1 XR PRO and XR2 PRO are the same gauze; XR2 PRO adds a second X-ray thread.

Build the system

The two-thread version, the alternatives, the bandage that holds the packing in, and trainers to practice on.

Free from MED-TAC
The Trauma Brief
MED-TAC's free trauma field guide, written by a physician and medical educator — what to do in the first minutes of a severe bleed, step by step.
Get the Brief ›

Questions buyers ask

▾Is ChitoGauze XR PRO evidence-based standard?

Yes. The TCCC Guidelines name ChitoGauze as an alternative hemostatic adjunct, with Combat Gauze the evidence-based hemostatic dressing of choice,1 and the Evidence-Based Standard Devices & Adjuncts list carries ChitoGauze under NSN 6510-01-591-77402 — the NSN of this item, Tricol 1090.4

▾What does "XR" mean?

X-ray detectable. A radiopaque thread is built into the gauze so the hospital team can see the dressing on an X-ray and confirm nothing is left in the wound.3,5

▾How long do I hold pressure?

At least 3 minutes of firm, direct pressure after packing, per the TCCC Guidelines, and until the bleeding is controlled, per Tricol's instructions.1,3 Then wrap a pressure bandage over the top.

▾Can I cut it?

Yes. If you cut it to a smaller size, make sure the radiopaque thread is in the piece you pack, and discard the unused portion.3

▾XR PRO or XR2 PRO?

Same 3 in. × 4 yd chitosan-coated gauze under the same FDA clearance; XR PRO has one X-ray thread and XR2 PRO has two.4,5,6 Units that order by NSN receive XR PRO, Tricol 1090.2,4

▾Is it safe for someone with a shellfish allergy?

It contains chitosan from shellfish.3 Allergy is a reaction to shellfish protein, and volunteers with documented shellfish allergy tolerated a HemCon chitosan bandage without reaction.16 In a life-threatening bleed, do not withhold it over a reported allergy; watch for signs of a reaction.

▾Does it work on someone taking blood thinners?

Pack and hold the same way, hold longer, and watch closely for re-bleeding. Twenty-one of the 66 patients in the Dutch EMS series were on anticoagulants or had a clotting disorder;10 in coagulopathic swine, survival with XR PRO was 71% against 86% for Combat Gauze.11

▾Is it antibacterial?

In laboratory testing submitted to the FDA, ChitoGauze reduced 26 bacterial strains — including MRSA, VRE and Acinetobacter baumannii — by at least 4 logs. FDA's summary notes the clinical value of those results has not been shown,5 so treat it as a hemostatic, not an antibiotic.

▾Where should it never go?

Never pack it into the chest or abdomen. Tricol's instructions: external use only, never implanted, not over the eyes and not near the spine.3

▾What if the bleeding doesn't stop?

Remove the packing and repack with a fresh dressing — ChitoGauze again or another hemostatic.1 Adding gauze on top of a pack that has failed does not stop the bleeding underneath it.

▾How should I store it?

Sealed and dry at 11–26 °C (52–78 °F).3 Keep kits out of hot vehicles, check the expiration date on the pouch, and replace any pouch with a broken seal or wet contents.3,6

Package & specifications

▾In the package — one sterile dressing
  • 1× HemCon® ChitoGauze® XR PRO hemostatic dressing, 3 in. × 4 yd (7.6 cm × 3.7 m), chitosan-coated nonwoven gauze, Z-folded
  • One radiopaque (X-ray-detectable) thread in the gauze
  • Sealed foil pouch
  • Sterile, single use. Pressure bandage and gloves sold separately.
▾Full specifications
Specification Detail
Manufacturer Tricol Biomedical, Inc. — HemCon® brand, Portland, Oregon, USA
Product HemCon® ChitoGauze® XR PRO hemostatic dressing
Manufacturer item 1090 — ChitoGauze® XR PRO, 3 in. × 4 yd; each or case of 50
NSN 6510-01-591-7740
GTIN 00870053000131 (each) · 50870053000136 (case of 50)
SKU 1020
Active agent Chitosan, coated on the gauze
Mechanism Positively charged chitosan draws red blood cells into a tight, adherent seal; works separately from the clotting cascade (manufacturer)
Gauze Polyester/rayon blend nonwoven medical gauze; 3 in. × 4 yd (7.6 cm × 3.7 m); Z-fold
X-ray detectable Yes — one radiopaque thread; radiopacity tested to ASTM F640
Labeled compression Apply pressure until bleeding is controlled (manufacturer); at least 3 minutes (TCCC Guidelines)
Heat None
Packaging Sealed foil pouch
Weight 0.7 oz (20 g)7,8
Sterility Sterile — gamma irradiation, sterility assurance level 10⁻⁶; single use
Storage 11–26 °C (52–78 °F), keep dry
Latex Not made with natural rubber latex
FDA 510(k) K102546, ChitoGauze XR — cleared 17 November 2010 for the external, temporary control of severely bleeding wounds
Warnings (manufacturer) External use only; do not implant. Do not apply over the eyes or use near the spine. Do not use if the seal is broken or the contents are wet. Use promptly after opening. Contains chitosan from shellfish. Single use; discard any unused portion; do not resterilize.
Intended user Trained emergency responders (manufacturer)
TCCC status evidence-based standard — ChitoGauze, alternative hemostatic adjunct (TCCC Guidelines, 1 May 2026); NSN on the Evidence-Based Standard Devices & Adjuncts list
▾References — 16 sources
  1. Committee on Tactical Combat Casualty Care. Tactical Combat Casualty Care (TCCC) Guidelines, 1 May 2026.
  2. Committee on Tactical Combat Casualty Care. Evidence-Based Standard Devices & Adjuncts, 15 December 2021.
  3. Tricol Biomedical, Inc. HemCon® ChitoGauze® XR PRO package insert and instructions for use, RM7255 Rev. 9 (11/2025).
  4. Tricol Biomedical, Inc. ChitoGauze® XR PRO product information, items 1090 and 1020; Our Science — chitosan-based products; About Tricol; FAQs.
  5. U.S. Food and Drug Administration. 510(k) K102546, ChitoGauze XR, HemCon Medical Technologies, Inc., cleared 17 November 2010; 510(k) summary; administrative product-code letter, 28 July 2023.
  6. National Library of Medicine. AccessGUDID device records: ChitoGauze®XR PRO 3" x 4 yds, catalog 1090 (DI 00870053000131); ChitoGauzeXR PRO, catalog 1020 (DI 00870053000568).
  7. North American Rescue. ChitoGauze® XR PRO product information sheet, item 30-0049 (REV073024).
  8. Safeguard Medical. ChitoGauze® XR PRO hemorrhage control overview (DTF054, 2023).
  9. Bennett BL, Littlejohn LF, Kheirabadi BS, Butler FK Jr, Kotwal RS, Dubick MA, Bailey HH. Management of external hemorrhage in Tactical Combat Casualty Care: chitosan-based hemostatic gauze dressings — TCCC Guidelines Change 13-05. J Spec Oper Med. 2014;14(3):40–57.
  10. Te Grotenhuis R, van Grunsven PM, Heutz WM, Tan EC. Prehospital use of hemostatic dressings in emergency medical services in the Netherlands: a prospective study of 66 cases. Injury. 2016;47(5):1007–1011.
  11. Gerling KA, Kersey AJ, Lauria AL, Mares JA, Hutzler JD, White PW, Abel B, Burmeister DM, Propper B, White JM. Evaluation of novel hemostatic agents in a coagulopathic swine model of junctional hemorrhage. J Trauma Acute Care Surg. 2023;95(2S Suppl 1):S144–S151.
  12. Rall JM, Cox JM, Songer AG, Cestero RF, Ross JD. Comparison of novel hemostatic dressings with QuikClot Combat Gauze in a standardized swine model of uncontrolled hemorrhage. J Trauma Acute Care Surg. 2013;75(2 Suppl 2):S150–S156.
  13. Schwartz RB, Reynolds BZ, Shiver SA, Lerner EB, Greenfield EM, Solis RA, Kimpel NA, Coule PL, McManus JG. Comparison of two packable hemostatic gauze dressings in a porcine hemorrhage model. Prehosp Emerg Care. 2011;15(4):477–482.
  14. Booms Z, Nguyen JQ, Smith B, et al. Assessment of hemostatic dressings for compressible wounds in a swine model simulating prolonged field care. Mil Med. 2026;191(5-6):e931–e937.
  15. Otrocka-Domagała I, Jastrzębski P, Adamiak Z, Paździor-Czapula K, Gesek M, Mikiewicz M, Rotkiewicz T. Safety of the long-term application of QuikClot Combat Gauze, ChitoGauze PRO and Celox Gauze in a femoral artery injury model in swine — a preliminary study. Pol J Vet Sci. 2016;19(2):337–343.
  16. Waibel KH, Haney B, Moore M, Whisman B, Gomez R. Safety of chitosan bandages in shellfish allergic patients. Mil Med. 2011;176(10):1153–1156.
Genuine HemCon® by Tricol Biomedical
Sourced direct from the manufacturer or an authorized master distributor. Ships from MED-TAC International, South Florida, US of A — clinician-founded, veteran-led, SDVOSB-certified.
SPECS & MEASUREMENTS

Specifications coming soon. Contact us for detailed product information.

SHIPPING & RETURNS

Domestic & Military Shipping

Free Standard Shipping: Automatically applied at checkout on all orders $200 and above within the 48 contiguous United States (CONUS).

APO/FPO Military Addresses: Unconditionally free standard shipping on every order, with no minimum purchase required.

Order Processing & Tracking

Fulfillment Timeline: In stock merchandise ships within 48-72 hours from Florida HQ.

Automated carrier tracking details are emailed immediately upon shipment dispatch.

30-Day Returns & Medical Safety

Returns: Unused, unopened equipment in original manufacturer packaging is eligible for return within 30 days of delivery.

Bio-Safety Notice: To ensure sterility and patient safety, medical consumables with opened or broken tamper-evident seals cannot be returned.

Return Facility: MED-TAC International Corp., 15757 Pines Blvd, Suite 154, Pembroke Pines, FL 33027.

Export Compliance

North American Rescue (NAR) products and rifle hard armor plates are strictly restricted to US and APO/FPO addresses and cannot be exported internationally.

FREQUENTLY ASKED QUESTIONS

Customer Reviews

Shopping cart

Your cart is empty.

Return to shop
Link copied to clipboard