0
Free US Shipping $200+  •  APO/FPO Always Ships Free Shop All →
Free US Shipping $200+ • APO/FPO Always Free ★ SDVOSB • CAGE: 9VFL3 • Medical SME-Led

SAM® Junctional Tourniquet (SJT)

Your Price: $410.97
Genuine, authorized product Ships from Florida HQ Free US shipping $200+ Physician & paramedic curated
Fulfillment Timeline: In stock merchandise ships within 48-72 hours from Florida HQ.
Buying 10+ for a department or team? Volume pricing available →
Request a custom quote for bulk orders, agency procurement, or government purchases
FREE APO/FPO SHIPPING • EVERY ORDER • NO MINIMUM

Guaranteed duty-free priority delivery to all deployed military postal codes worldwide.

SAM® Junctional Tourniquet (SJT)
$410.97
PRODUCT INFORMATION
SAM Medical · Junctional Tourniquet
SAM® Junctional Tourniquet (SJT)
A belt with an AUTOSTOP buckle that clicks when the belt reaches its set force, and a hand-pumped Target Compression Device that presses down on the artery feeding the bleed. The SJT is FDA-cleared to control difficult bleeding in the groin and the armpit and to immobilize a pelvic fracture. This is the JT400-EN kit: belt, two Target Compression Devices, extender, auxiliary strap and hand pump.
FDA-cleared · K123694 · K131561Groin · armpit · pelvic fractureTwo compression devices — both groinsUp to 4 hoursNSN 6515-01-618-7475

One belt, three jobs — groin, armpit and pelvis — and the buckle tells you by sound and feel when the belt force is right to inflate.

The short answer
What it is
A pneumatic junctional tourniquet: a belt with a force-limiting AUTOSTOP buckle and inflatable Target Compression Devices (TCDs) set over the bleeding artery.
Use it for
Groin or armpit bleeding a limb tourniquet cannot control, and immobilizing a suspected pelvic fracture.
How it's used
Pack and press the wound while it is readied. Set the TCD over the target, buckle the belt and pull the brown handles until the buckle clicks, then pump the TCD until the bleeding stops.
Who carries it
Combat and tactical medics, flight and transport teams, and EMS agencies with a junctional-hemorrhage protocol — an aid-bag device for trained providers.

At a glance

Cleared for
Groin and armpit bleeding; pelvic fracture
FDA
510(k) K123694 · K131561
Mechanism
Pneumatic TCD + AUTOSTOP buckle
Belt force
150 N at the buckle click
TCD lift
Inflates up to 3.2 in.
Labeled use
Up to 4 hours
Weight
24 oz (680 g)
Packaged size
4.75 × 4.75 × 8.875 in.
NSN
6515-01-618-7475
Manufacturer item
SAM JT400-EN

12 things to know about the SAM Junctional Tourniquet

What it is cleared for, how the buckle and compression device work, and what the studies found.

  1. 01

    One belt, three cleared jobs

    The SJT is FDA-cleared for battlefield and trauma situations to control difficult bleeds in the inguinal area and in the axilla area, and to immobilize a pelvic fracture.4,5 The groin and pelvic indications were cleared in March 2013 and the armpit in July 2013.4,5 Junctional sites accounted for 19.2% of the potentially survivable hemorrhage deaths among U.S. combat fatalities from 2001 to 2011.20

  2. 02

    The buckle sets the belt force for you

    Pull the brown handles apart and the AUTOSTOP buckle clicks once the belt reaches its optimal force — 150 N of circumferential pressure, the point where its prongs extend through the precision strap.6,7 The clearance describes this as feedback that a minimum belt force has been reached, after which the compression device is inflated.4

  3. 03

    The Target Compression Device does the arterial work

    The TCD inflates with the removable hand pump or any luer-lock syringe and rises up to 3.2 in. over its target.7 It can press directly on an artery or over a hemostatic dressing; when it sits directly over a wound, SAM directs sterile gauze or a hemostatic dressing underneath it.5,6 In perfused cadavers it occluded the artery above the groin at a mean 107 mmHg, against 139 mmHg for manual pressure, and the armpit artery at 739 mmHg against 1,237.10

  4. 04

    Two compression devices cover both groins

    The JT400-EN kit ships two TCDs, so both groins can be compressed from one belt. The JT401-EN kit carries a single TCD and no extender or auxiliary strap.6,7

  5. 05

    The armpit takes the extender and the auxiliary strap

    For axillary bleeding the belt goes under the arms as high as possible, with its D-ring on the injured side in line with the side of the neck. The extender fits over the TCD for the anatomy below the collarbone, and the auxiliary strap runs from the D-ring to the back of the belt near the midline before the TCD is pumped up.6,7

  6. 06

    Pelvic mode: no TCD, belt at the hips

    To immobilize a pelvic fracture, slide the belt under the casualty without the TCD, at the level of the trochanters — the bony points of the hips — and buckle it until it clicks.6 The clearance used SAM's own Pelvic Sling as a predicate device.4 The TCCC Guidelines call for a pelvic binder whenever a pelvic fracture is suspected after severe blunt or blast injury.1

  7. 07

    Altitude changes the inflation

    SAM warns that changes in altitude may call for additional pumping, and that when altitude change is a concern the TCD can be filled by syringe with water, saline or another non-compressible fluid instead of air.6 Flight and mountain teams should train that option.

  8. 08

    Labeled for up to four hours

    SAM labels the SJT to control junctional bleeding for up to 4 hours where standard tourniquets cannot be used.6 In prolonged use as a pelvic sling, check the skin underneath for pressure injury.6

  9. 09

    Packing and pressure come first while it's readied

    The TCCC Guidelines direct a junctional tourniquet immediately when the bleeding site is amenable to one, with no delay once it is ready — and hemostatic dressings with direct pressure if a junctional tourniquet is not available or while it is being readied.1 With the SJT the packing does not have to come out: the TCD goes on over it.5,6

  10. 10

    What the volunteer studies found

    In human volunteers, the CRoC, SJT and JETT were the most effective of four junctional models, and the CRoC and SJT were the fastest.12 In 84 healthy volunteers in battle dress, tested after exercise, the SJT and CRoC each stopped popliteal flow in almost 90% and the SJT went on faster.14 On a bleeding groin manikin, the CRoC and SJT lost the least simulated blood.16 A meta-analysis put average SJT effectiveness at 87%, with a mean application time of 101 seconds.19

  11. 11

    Transport and training are the weak points

    When 49 corpsmen applied three devices to one another, the SJT held better than the JETT after a short transport — but no device performed well, at 24–48% effectiveness.13 In a Fort Hood trial only 28% of combat lifesavers and 40% of combat medics placed both the SJT and the JETT successfully, though both groups preferred the SJT;15 chemical-protective (MOPP) gear slowed application from 167 to 223 seconds.17

  12. 12

    Battlefield use and Clinical evaluation

    The first known prehospital use of the SJT was on a battlefield casualty with groin bleeding in Afghanistan.11 The 2019 Evidence-Based Standard Devices list named it as the SAM-JT (NSN 6515-01-618-74759) with the CRoC and the JETT;3 the current list, dated 15 December 2021, names no specific junctional product and leaves the choice to any FDA-cleared device indicated for junctional hemorrhage control.2 The SJT meets that criterion; it is not evidence-based standard by name.

How to apply the SJT to the groin

SAM Medical's inguinal instructions in order, with the TCCC step that comes before them.

  1. 1
    Control it by hand first. Pack the wound with hemostatic gauze and hold firm direct pressure while a teammate readies the SJT.1
  2. 2
    Clear the site. Remove objects from the casualty's pockets and clothing where the belt and TCD will sit.6
  3. 3
    Slide the belt under and place the TCD. Pass the belt under the casualty and set the TCD over the area to be compressed — over sterile gauze or a hemostatic dressing if it sits directly on the wound. For both groins, use the second TCD.6
  4. 4
    Buckle it. Hold the TCD in place and connect the belt with the buckle.6
  5. 5
    Pull until it clicks. Pull the brown handles away from each other until the buckle secures with an audible click, then press the excess belt down onto the hook-and-loop. A second click may follow as the belt settles.6
  6. 6
    Pump the TCD. Inflate with the hand pump until the bleeding stops.6
  7. 7
    Record the time. Write the application time on the casualty card, as for any tourniquet.1
  8. 8
    Monitor and hand it off. Recheck bleeding control through transport and adjust the device as needed; it is labeled for up to 4 hours.6 Removal — unbuckling the belt — is for the receiving clinicians.
Armpit and pelvis. For the armpit: belt under the arms as high as possible, D-ring on the injured side, extender on the TCD, auxiliary strap from the D-ring to the back of the belt, then pump. For a pelvic fracture: belt at the hips without the TCD, buckled until it clicks.6 Train on the trainer: SAM makes a JT402-EN trainer kit; the live device is single use, and SAM warns that reuse may cause infection or reduced performance.6,8

Where it fits

Use it for
  • Groin bleeding a limb tourniquet cannot control — one side or both
  • Armpit bleeding, with the extender and auxiliary strap
  • Immobilizing a suspected pelvic fracture, belt only
  • Holding pressure over a packed junctional wound so your hands are free
Not for
  • Limb bleeding a tourniquet can control — limb tourniquet first1
  • Use beyond 4 hours6
  • Pelvic-binder use with the TCD in place — the belt goes on without it6
  • Reuse after a casualty or after training — single use6

The evidence

Every study cited above, what it tested, and how strong the evidence is.

Study Evidence type What was studied What it found
Johnson et al., J Spec Oper Med 2014 Cadaver · perfused model SJT on perfused cadavers, simulated groin and armpit bleeding Mean 107 mmHg occluded the distal external iliac artery (manual pressure 139); 739 mmHg the axillary artery (manual 1,237); no tissue damage
Kragh et al., Prehosp Emerg Care 2015 Human · volunteers CRoC, AAJT, JETT and SJT on 10 volunteers; distal pulse by Doppler CRoC, SJT and JETT most effective, no significant difference; CRoC and SJT fastest
Meusnier et al., J Spec Oper Med 2016 Human · randomized volunteers CRoC vs SJT, 84 healthy volunteers in battle dress after exercise Almost 90% effective with either device; SJT faster and preferred
Gaspary et al., Prehosp Emerg Care 2019 Human · randomized volunteers CRoC, JETT and SJT applied by 49 corpsmen to fellow participants, then a short transport SJT and JETT faster than CRoC; after transport SJT held better than JETT, all 24–48%; SJT ranked first by users
Flecha et al., Mil Med Res 2018 Manikin · randomized crossover SJT and JETT applied by 133 combat lifesavers and 94 combat medics 28% of combat lifesavers and 40% of medics placed both successfully; both groups preferred the SJT
Kragh et al., Prehosp Disaster Med 2016 Manikin CRoC, JETT and SJT, 30 users, 270 tests on a bleeding groin manikin All controlled the bleeding; CRoC and SJT had the least blood loss
Wagner et al., Mil Med 2020 Manikin · randomized SJT applied by 49 combat medics with and without MOPP chemical-protective gear 223 s vs 167 s with MOPP gear; success 64% vs 81% (not significant)
Zhao et al., Chin J Traumatol 2023 Animal · randomized swine SJT on axillary bleeding at 210 mmHg for 2 hours, 18 swine Bleeding controlled; spontaneously breathing animals had respiratory arrest after 2 hours; ventilation lessened the effect
Smith et al., J Trauma Acute Care Surg 2019 Expert review · meta-analysis Eight healthy-volunteer studies of four junctional devices Average effectiveness SJT 87%, JETT 83%, CRoC 95%; mean application 101 s for SJT
Klotz et al., J Spec Oper Med 2014 Human · case report Battlefield casualty with groin bleeding, Afghanistan First known prehospital use of the SJT
Eastridge et al., J Trauma Acute Care Surg 2012 Human · mortality review 4,596 U.S. battlefield deaths, 2001–2011 Junctional sites accounted for 19.2% of potentially survivable hemorrhage deaths

No trial has measured survival with any junctional tourniquet. The device evidence is cadaver, swine, manikin and healthy-volunteer work plus case reports — read it as mechanism, speed and usability, not as proof of outcome.

How it compares

The four FDA-cleared junctional devices a buyer weighs, side by side.

SAM Junctional Tourniquet JETT AAJT-S CRoC
Mechanism Hand-pumped target compression device on a force-limiting belt Two screw-down pressure pads on a belt Hand-pumped wedge bladder on a ratcheting belt Aluminum clamp with a screw-down pressure disc
FDA-cleared for Inguinal and axillary bleeding; pelvic fracture immobilization Inguinal bleeding Bleeding in the pelvis, inguinal area and axilla; pelvic fracture stabilization Inguinal and axillary bleeding; last resort for carotid bleeding
Both groins from one device Yes — the JT400-EN kit carries two compression devices Yes — two pads Abdominal placement stops flow to both legs No — one clamp per side
Labeled maximum 4 h 4 h 4 h groin or armpit · 1 h abdomen 4 h
Weight 24 oz (JT400-EN) 1 lb 8 oz 25 oz 1.25 lb
Volunteer effectiveness (meta-analysis) 87% 83% Earlier AAJT: 52% abdominal; groin 100% in 2 studies 95%
Mean application time (meta-analysis) 101 s 130 s Earlier AAJT, abdominal: 92 s and 171 s 101 s
Named on the 2019 evidence-based list Yes Yes No Yes
evidence-based standard today No — the current list names no junctional device No — the current list names no junctional device No — the current list names no junctional device No — the current list names no junctional device

Indications and labeled times come from each device's FDA 510(k) record and instructions;4,5,6,21,22,23 weights from the manufacturers' published specifications;7,21,22,23 effectiveness and application times are averages from healthy-volunteer studies.19 The current evidence-based list names no junctional product at all;2 absence from it does not by itself mean a device was tested and failed.

Build the system

The packing that goes in first, the other junctional options, a dedicated pelvic binder and the training aid.

Free from MED-TAC
The Trauma Brief
MED-TAC's free trauma field guide, written by a physician and medical educator — what to do in the first minutes of a severe bleed, step by step.
Get the Brief ›

Questions buyers ask

▾Is the SAM Junctional Tourniquet evidence-based standard?

Not by name today. The 2019 Evidence-Based Standard Devices list named it as the SAM-JT, with the CRoC and the JETT.3 The current list, dated 15 December 2021, names no specific junctional product and leaves the choice to any FDA-cleared device indicated for junctional hemorrhage control;2 the SJT, cleared for groin and armpit bleeding, meets that criterion.4,5

▾JT400-EN or JT401-EN — what's the difference?

The JT400-EN is the full kit: belt, two TCDs, TCD extender, hand pump and auxiliary strap, under NSN 6515-01-618-7475. The JT401-EN is a belt, one TCD and a hand pump, with no extender or auxiliary strap — so it cannot do a bilateral groin application or the full armpit setup.6,7

▾Can it control bleeding from the armpit?

Yes — the axillary indication was added in July 2013.5 It uses the extender and the auxiliary strap.6 Watch the breathing: in swine with an axillary SJT held for 2 hours, spontaneously breathing animals developed respiratory arrest, and mechanical ventilation lessened the effect.18

▾Can it be used as a pelvic binder?

Yes. Immobilizing a pelvic fracture is a cleared indication: the belt goes on at the level of the hips without the TCD and is buckled until it clicks.4,6

▾Should I pack the wound first?

Yes, while the SJT is being readied — the TCCC Guidelines call for hemostatic dressings with direct pressure until the junctional tourniquet is ready, then immediate application.1 Leave the packing in: the TCD goes over sterile gauze or a hemostatic dressing.6

▾How long can it stay on?

SAM labels it for up to 4 hours.6 Removal is for the receiving clinicians; in long use as a pelvic sling, check the skin for pressure injury.6

▾Does altitude affect it?

It can. SAM warns that altitude changes may call for additional pumping, and that the TCD can be filled by syringe with water or saline when altitude change is a concern.6

▾Can the casualty be X-rayed, scanned or put in an MRI with it on?

All materials are radiolucent except the buckle's two stainless-steel springs, so X-ray and CT can proceed with the device in place; it is labeled MR Conditional at 3 T.7 Used as a pelvic sling, it should stay firmly attached to the patient in the MRI room.6

▾Can it be reused? Is there a trainer?

The SJT is single use; SAM warns that reuse may cause infection or reduced performance.6 For practice, SAM makes the JT402-EN trainer kit.8

▾Who should carry it?

Providers trained on it. Success rates in field-style testing were low without practice — 28% of combat lifesavers and 40% of medics placed both junctional devices successfully in one trial.15 It rides in the aid bag or vehicle kit in its pouch.

Package & specifications

▾In the package — JT400-EN kit
  • 1× SAM® Junctional Tourniquet belt with AUTOSTOP buckle and precision strap; quick-reference instructions printed inside the belt
  • 2× Target Compression Devices (TCDs)
  • 1× TCD extender for axillary application
  • 1× auxiliary strap
  • 1× removable hand pump
  • Durable carry pouch and instructions for use. Non-sterile, single use.
▾Full specifications
Specification Detail
Manufacturer SAM Medical Products — Tualatin, Oregon
Product SAM® Junctional Tourniquet (SJT), kit JT400-EN
Kit contents Belt with AUTOSTOP buckle · 2 Target Compression Devices · TCD extender · hand pump · auxiliary strap · pouch
NSN 6515-01-618-7475 · 6515-01-646-2617
GTIN (UDI-DI) 00822045000353
FDA 510(k) K123694, cleared 7 March 2013 (groin bleeding, pelvic fracture); K131561, cleared 24 July 2013 (adds armpit bleeding) — Class II, product code DXC
Cleared indications Battlefield and trauma situations: to control difficult bleeds in the inguinal area; to control difficult bleeds in the axilla area; to immobilize a pelvic fracture
Mechanism Pneumatic Target Compression Device on a belt with force-limiting AUTOSTOP buckle
Belt force Optimal force at 150 N circumferential, signaled by the buckle click
TCD Inflates up to 3.2 in. by hand pump or luer-lock syringe
Labeled use Up to 4 hours
Packaged size 4.75 × 4.75 × 8.875 in. (12.1 × 12.1 × 22.5 cm)
Weight 24 oz (680 g)
Imaging Radiolucent except the buckle's two stainless-steel springs; MR Conditional 3 T
Sterility / use Non-sterile, single use
Other SAM configurations JT401-EN — belt, 1 TCD, hand pump, 18 oz · JT402-EN — trainer kit
Clinical evaluation Named as SAM-JT on the 2019 Evidence-Based Standard Devices list; the current list (15 Dec 2021) names no specific junctional device
▾References — 23 sources
  1. Committee on Tactical Combat Casualty Care. Tactical Combat Casualty Care (TCCC) Guidelines, 1 May 2026.
  2. Committee on Tactical Combat Casualty Care. Evidence-Based Standard Devices & Adjuncts, 15 December 2021.
  3. Committee on Tactical Combat Casualty Care. Evidence-Based Standard Devices & Adjuncts, 1 August 2019 (Junctional Tourniquets & Devices: CRoC, SAM-JT, JETT).
  4. U.S. Food and Drug Administration. 510(k) K123694, SAM Junctional Tourniquet, SAM Medical Products, cleared 7 March 2013 — 510(k) summary and indications for use.
  5. U.S. Food and Drug Administration. 510(k) K131561, SAM® Junctional Tourniquet (axilla indication), SAM Medical Products, cleared 24 July 2013 — 510(k) summary and indications for use.
  6. SAM Medical Products. SAM® Junctional Tourniquet Instructions for Use, JT-IS-EN-05 (issue date 2025-08).
  7. SAM Medical Products. SAM® Junctional Tourniquet product specification sheet SJT-SS-05 and product page.
  8. National Library of Medicine. AccessGUDID device records 00822045000353 (JT400-EN), 00822045000360 (JT401-EN) and 00822045000346 (JT402-EN trainer).
  9. Defense Logistics Agency. Federal Logistics Information System records, NSN 6515-01-618-7475 (Tourniquet Kit, Junctional Compression — SAM junctional tourniquet) and NSN 6515-01-646-2617 (SAM junctional tourniquet with bag).
  10. Johnson JE, Sims K, Hamilton DJ, Kragh JF Jr. Safety and effectiveness evidence of SAM® Junctional Tourniquet to control inguinal hemorrhage in a perfused cadaver model. J Spec Oper Med. 2014;14(2):21–25.
  11. Klotz JK, Leo M, Andersen BL, et al. First case report of SAM® Junctional Tourniquet use in Afghanistan to control inguinal hemorrhage on the battlefield. J Spec Oper Med. 2014;14(2):1–5.
  12. Kragh JF Jr, Kotwal RS, Cap AP, et al. Performance of junctional tourniquets in normal human volunteers. Prehosp Emerg Care. 2015;19(3):391–398.
  13. Gaspary MJ, Zarow GJ, Barry MJ, et al. Comparison of three junctional tourniquets using a randomized trial design. Prehosp Emerg Care. 2019;23(2):187–194.
  14. Meusnier JG, Dewar C, Mavrovi E, et al. Evaluation of two junctional tourniquets used on the battlefield: Combat Ready Clamp® versus SAM® Junctional Tourniquet. J Spec Oper Med. 2016;16(3):41–46.
  15. Flecha I, Naylor JF, Schauer SG, Curtis RA, Cunningham CW. Combat lifesaver-trained, first-responder application of junctional tourniquets: a prospective, randomized, crossover trial. Mil Med Res. 2018;5(1):31.
  16. Kragh JF Jr, Lunati MP, Kharod CU, et al. Assessment of groin application of junctional tourniquets in a manikin model. Prehosp Disaster Med. 2016;31(4):358–363.
  17. Wagner EM, Naylor JF, Ahern BJ, et al. Effects of MOPP gear on SAM Medical Junctional Tourniquet application: a prospective, randomized control trial. Mil Med. 2020;185(9-10):e1810–e1816.
  18. Zhao DC, Zhang HY, Guo Y, et al. Effect of SAM junctional tourniquet on respiration when applied in the axilla: a swine model. Chin J Traumatol. 2023;26(3):131–138.
  19. Smith S, White J, Wanis KN, et al. The effectiveness of junctional tourniquets: a systematic review and meta-analysis. J Trauma Acute Care Surg. 2019;86(3):532–539.
  20. Eastridge BJ, Mabry RL, Seguin P, et al. Death on the battlefield (2001–2011): implications for the future of combat casualty care. J Trauma Acute Care Surg. 2012;73(6 Suppl 5):S431–S437.
  21. U.S. Food and Drug Administration. 510(k) K123194, Junctional Emergency Treatment Tool, North American Rescue, cleared 3 January 2013; North American Rescue, JETT Instructions for Use ZZ-0450 and product information sheet, item 30-0088.
  22. U.S. Food and Drug Administration. 510(k) K221661, Abdominal Aortic and Junctional Tourniquet – Stabilized (AAJT-S), Compression Works, cleared 3 March 2023; North American Rescue, AAJT-S product information sheet, item 30-0248 (REV101625); Compression Works, AAJT-S Instructions for Use (US rev 002).
  23. U.S. Food and Drug Administration. 510(k) K130482 (29 April 2013) and K141685 (26 January 2015), Combat Ready Clamp (CRoC), Combat Medical Systems — indications, 4-hour use, 1.25 lb with disc.
Genuine SAM Medical
Sourced direct from the manufacturer or an authorized master distributor. Ships from MED-TAC International, South Florida, US of A — clinician-founded, veteran-led, SDVOSB-certified.
SPECS & MEASUREMENTS

Specifications coming soon. Contact us for detailed product information.

SHIPPING & RETURNS

Domestic & Military Shipping

Free Standard Shipping: Automatically applied at checkout on all orders $200 and above within the 48 contiguous United States (CONUS).

APO/FPO Military Addresses: Unconditionally free standard shipping on every order, with no minimum purchase required.

Order Processing & Tracking

Fulfillment Timeline: In stock merchandise ships within 48-72 hours from Florida HQ.

Automated carrier tracking details are emailed immediately upon shipment dispatch.

30-Day Returns & Medical Safety

Returns: Unused, unopened equipment in original manufacturer packaging is eligible for return within 30 days of delivery.

Bio-Safety Notice: To ensure sterility and patient safety, medical consumables with opened or broken tamper-evident seals cannot be returned.

Return Facility: MED-TAC International Corp., 15757 Pines Blvd, Suite 154, Pembroke Pines, FL 33027.

Export Compliance

North American Rescue (NAR) products and rifle hard armor plates are strictly restricted to US and APO/FPO addresses and cannot be exported internationally.

FREQUENTLY ASKED QUESTIONS

Shopping cart

Your cart is empty.

Return to shop
Link copied to clipboard