0
Free US Shipping $200+  •  APO/FPO Always Ships Free Shop All →
Free US Shipping $200+ • APO/FPO Always Free ★ SDVOSB • CAGE: 9VFL3 • Medical SME-Led

HALO™ Vent Chest Seal — IFAK Two Pack

(4 reviews)
$20.59
Request a custom quote for bulk orders, agency procurement, or government purchases
FREE APO/FPO SHIPPING • EVERY ORDER • NO MINIMUM

Guaranteed duty-free priority delivery to all deployed military postal codes worldwide.

Ships from Florida HQ Free Shipping $200+ CONUS Free APO/FPO Shipping 30-Day Unopened Returns
Fulfillment Timeline: In stock merchandise ships within 48-72 hours from Florida HQ.
$20.59
PRODUCT INFORMATION
HALO™ by Medical Devices, Inc. · Vented Chest Seal
HALO™ Vent Chest Seal — IFAK Two Pack
Two vented HALO Vent chest seals folded into one 5.5 × 7.5 in. IFAK pouch — one for the entry wound, one for the exit. Each 8.35 × 6.06 in. seal pairs a scrim-reinforced hydrogel with an outer tape edge; a hydrogel-free center sits over the wound and four vents around it let air escape as the casualty breathes out. Made in the USA by Medical Devices, Inc. of Romulus, Michigan.
Vented — four vents2 seals per pouch8.35 × 6.06 in. each−30 °F to 140 °F6-year shelf life

An open chest wound usually has a second hole you have not seen yet. Two vented seals in one pouch means both holes get the same seal — after you check the back.

The short answer
What it is
Two vented occlusive chest seals in one IFAK-size pouch: transparent backing, hydrogel plus an outer tape edge, four vents and a large pull tab.
Use it for
An open or sucking chest wound — front, back or side — and its exit wound. The TCCC Guidelines call for a vented chest seal first.1
How it's used
Wipe the skin, peel the liner, center the hydrogel-free window over the hole and press it on without stretching. Then watch the casualty's breathing; if it gets worse, burp the seal.
Who carries it
Military, law enforcement, EMS and fire, and trained civilians — in the IFAK beside the tourniquet, the packing gauze and the pressure dressing.

At a glance

Type
Vented — four vents
Seals per pack
2 HALO Vent
Seal size
8.35 × 6.06 in. (21.2 × 15.4 cm)
Pouch
5.5 × 7.5 in. IFAK — seals folded in thirds
Adhesive
Scrim-reinforced hydrogel + outer tape edge
Temperature rating
−30 °F to 140 °F (−34 °C to 60 °C)
Shelf life
6 years
Latex
Latex-free
Manufacturer item
US 1216-10020
FDA
Class I, 510(k)-exempt

12 things to know about the HALO Vent

What the vent does, why the TCCC Guidelines put vented seals first, and what the research does and does not show.

  1. 01

    Vented first is the TCCC position

    The TCCC Guidelines dated 1 May 2026 direct that every open or sucking chest wound be treated by immediately applying a vented chest seal; if a vented seal is not available, a non-vented one is used. Either way, the casualty is then monitored for a developing tension pneumothorax.1 What is in the kit is what goes on: among U.S. casualties with chest wounds in Afghanistan, most of the seals placed were not vented.15

  2. 02

    Why the vent matters

    Sealing the hole stops air being drawn in through the chest wall, but an injured lung can keep leaking air inside the chest. In pigs with an ongoing air leak, an unvented seal led to tension pneumothorax in every animal after about 1.4 L of air, while a vented seal held through 2 L.10 That research drove the 2013 change to vented-first.9

  3. 03

    How the HALO Vent vents

    The center of the seal is a hydrogel-free window that goes over the wound. When pressure builds inside the chest, air lifts the cover layer and escapes through vents; when pressure drops, the cover settles back and keeps the seal. Four vents sit around the dressing so it can drain whichever way the casualty is lying.3,8

  4. 04

    Two seals for two holes

    A bullet or blade that goes in often comes out. The instructions direct a second seal on any additional chest wound,4 and this pouch carries it. Check the back, the sides and the armpits — an exit wound on the back is the one most often missed.

  5. 05

    Big enough to find clean skin

    Each seal measures 8.35 × 6.06 in. (21.2 × 15.4 cm), and Medical Devices, Inc. makes the HALO Vent in that one size.3,5 The adhesive has to land on intact skin all the way around the wound, which is why a large seal forgives an off-center placement under stress.

  6. 06

    Two adhesives, not one

    A hydrogel infused with scrim — a reinforcing mesh that adds strength and limits gel migration — does the main work, and an outer tape edge adds a second adhesion zone. The manufacturer states it adheres in damp, dry, sandy and hairy conditions, and in the presence of moisture, pleural fluid or blood.3,4 The first step in the instructions is still to clean and dry the area.

  7. 07

    Built for gloved, bloody hands

    An oversized release liner, a large pull tab and transparent construction let you see the wound through the seal and put the window where it belongs.3 The same tab gives you a grip to lift an edge if the seal needs burping.

  8. 08

    Rated −30 °F to 140 °F, six-year shelf life

    Medical Devices, Inc. rates the HALO Vent from −30 °F to 140 °F (−34 °C to 60 °C) with a six-year shelf life, and its FDA device record lists the same storage and handling range.3,7 It is non-sterile, latex-free and single use.4,7

  9. 09

    Keep the vents clear

    The instructions warn against placing the HALO Vent where the casualty's body weight or other equipment can block the vents, and against placing it over a protruding object, which can worsen the injury or damage the vents.4

  10. 10

    Vented does not mean set-and-forget

    Vent designs perform differently. With a bleeding chest wound in pigs, success ranged from 6 of 6 to 0 of 4 across five vented brands; blood clogged or lifted off the one-way-valve designs.11 The HALO Vent was not one of the five, and a 2021 systematic review judged the evidence on individual brands limited.14 Whatever seal is on, keep watching the casualty's breathing.

  11. 11

    Not on the evidence-based device list — and no chest seal is

    The Evidence-Based Standard Devices & Adjuncts list dated 15 December 2021 names tourniquets and hemostatic dressings; it names no chest seal, so the HALO Vent is not evidence-based standard.2 Absence from the list does not by itself mean a product was tested and failed. The TCCC Guidelines specify the device type: vented.1

  12. 12

    Made in Michigan since 2009

    Medical Devices, Inc., founded in 1982, launched the HALO chest seal in 2009, manufactures in the United States and works under an ISO 13485 quality system.5 The HALO Vent is an FDA-registered, Class I (510(k)-exempt) occlusive wound dressing.6

How to apply the HALO Vent

The sequence from the manufacturer's instructions and the TCCC Guidelines, with the exit-wound check built in.

  1. 1
    Expose and find every hole. Cut clothing away and look and feel front, back, sides and armpits. Life-threatening bleeding is controlled first — tourniquet, packing, pressure dressing.
  2. 2
    Cover it now. Put a gloved hand over the hole — or have the casualty do it — while you open the pouch at a tear notch.
  3. 3
    Wipe it. Clean and dry the skin around the wound: blood, sweat and debris all fight the adhesive.4
  4. 4
    Peel and aim. Remove the clear liner without letting the gel touch anything else, then place the seal gel side down with the vent centered over the wound.4
  5. 5
    Press, don't stretch. Smooth it on with light pressure from the center out. Do not stretch the seal.4
  6. 6
    Seal the exit. Apply the second seal the same way on any other chest wound you found.4
  7. 7
    Position and watch. Unconscious and breathing: recovery position. Conscious: let them sit up or take whatever position helps them breathe.1 Watch for worsening shortness of breath, a rising breathing rate, a racing pulse, blue lips or falling oxygen readings.1,4
  8. 8
    Worse? Burp it. Lift an edge with the pull tab to let trapped air escape, then press it back down — or remove the seal. Trained providers follow the Guidelines' decompression direction if breathing does not improve.1,4
  9. 9
    Hand it off. Tell the receiving team how many seals are on and where, and keep reassessing during transport.4
Train before you need it. Practice the wipe-peel-place-burp sequence on a chest seal trainer. Every chest seal is single use — one opened for practice does not go back into a kit.

Where it fits

Use it for
  • Open or sucking chest wounds — the device type the TCCC Guidelines call for first1
  • Entry and exit wounds from the same injury — two seals in one pouch
  • Wounds on wet, hairy or bloody skin, once the skin has been wiped3,4
  • IFAKs, plate-carrier pouches and vehicle kits where space is tight
Not for
  • Packing — never pack gauze into a chest or abdominal wound
  • Over a protruding or impaled object — stabilize the object instead4
  • Post-surgical wounds — a listed contraindication4
  • Limb bleeding — that is the tourniquet, packing gauze and pressure dressing
  • Practice — train on a chest seal trainer, not a live seal

The evidence

Every study cited above, what it tested, and how strong it is.

Study Evidence type What was studied What it found
Kheirabadi et al., J Trauma Acute Care Surg 2013 Animal · crossover Unvented HALO vs vented Bolin seal on an open chest wound with an ongoing air leak, 8 swine Both restored breathing within 5 min; the unvented seal led to tension pneumothorax in all 8 after ~1.4 L of air, the vented seal held through 2 L
Kheirabadi et al., J Trauma Acute Care Surg 2017 Animal · comparative Five vented seals on a bleeding open chest wound (hemopneumothorax), 26 swine Success: Russell 6/6, Sentinel 6/6, HyFin Vent 4/6, SAM 1/4, Bolin 0/4; one-way valves clotted or detached
Kotora et al., J Emerg Med 2013 Animal · comparative HyFin, Sentinel and SAM vented seals, communicating pneumothorax, 24 swine All three evacuated air and blood; no tension physiology developed with a seal in place
Arnaud et al., Injury 2016 Animal · adhesion Vented seals on soiled live swine skin, at room temperature and after extreme cold and heat storage Russell, FastBreathe, HyFin and SAM adhered similarly; Bolin adhesion fell after temperature extremes
Schachner et al., Ann Thorac Surg 2022 Bench · ex vivo Improvised seals on a pig chest wall with a simulated open pneumothorax Wet rescue-blanket squares sealed 5 of 5; plastic foil from a gauze wrapper sealed 0 of 5
Schauer et al., J Spec Oper Med 2017 Human · combat registry 62 U.S. casualties with gunshot or puncture wounds to the chest, Afghanistan 74.2% received a chest seal; most seals placed were not vented
Butler et al., J Spec Oper Med 2013 Expert review · TCCC change 13-02 evidence-based review of open pneumothorax care after the 2013 swine data Vented chest seal first; non-vented if no vented seal; monitor, burp or remove, decompress
Margolis et al., J Spec Oper Med 2014 Expert consensus · C-TECC Committee for Tactical Emergency Casualty Care review of vented vs non-vented seals Vented seals likely add benefit; non-vented users reassess, burp and decompress; no clear outcome superiority proven
Paquette et al., J Spec Oper Med 2021 Systematic review Six quantitative chest seal studies, 1990–2020; one used human participants (adhesion only) HyFin Vent and Russell best supported; evidence on individual devices is limited
Lyng et al. (NAEMSP), Prehosp Emerg Care 2024 Expert review · position statement Structured review of EMS traumatic pneumothorax care EMS may consider a vented seal in a spontaneously breathing patient; seals may be harmful during positive-pressure ventilation

Strongest to weakest: human data, then animal studies, then bench work. Every brand-to-brand comparison of chest seals is in pigs or on pig skin; the HALO non-vented seal was the unvented arm of the 2013 study, and the HALO Vent was not among the vented seals compared.

How it compares

The vented and non-vented seals a buyer most often weighs against the HALO Vent.

HALO Vent (2-pack) HALO Seal (2-pack) HyFin Vent (twin pack) Russell Chest Seal
Maker Medical Devices, Inc. Medical Devices, Inc. North American Rescue Safeguard Medical
Vented Yes — four vents around a hydrogel-free center No — fully occlusive Yes — channel vent Yes — four-aperture valve
Seals per pack 2 2 2 1
Published swine data Not among the brands compared Unvented arm, 2013: tension pneumothorax in 8 of 8 with an ongoing air leak10 Held in 4 of 6 with a bleeding chest wound;11 no tension pneumothorax in a communicating model12 Held in 6 of 6 with a bleeding chest wound11
evidence-based standard No No No No

The Evidence-Based Standard Devices & Adjuncts list (15 December 2021) names no chest seal of any brand;2 absence from the list does not by itself mean a product was tested and failed. Both HALO seals measure 8.35 × 6.06 in.3

Build the system

The rest of the HALO line, the alternatives, a trainer, and the other three jobs in the kit.

Free from MED-TAC
The Trauma Brief
MED-TAC's free trauma field guide, written by a physician and medical educator — what to do in the first minutes of a severe bleed, step by step.
Get the Brief ›

Questions buyers ask

▾Is the HALO Vent evidence-based standard?

No. The Evidence-Based Standard Devices & Adjuncts list dated 15 December 2021 names no chest seal of any brand.2 That is not a finding against the HALO Vent — absence from the list does not by itself mean a product was tested and failed. What the TCCC Guidelines do specify is the type: a vented chest seal first.1

▾Vented or non-vented — which should I carry?

Vented, when you have the choice: the TCCC Guidelines call for a vented seal first and a non-vented seal when no vented seal is available.1 The civilian-focused C-TECC reached a similar view in 2014 — vented seals likely add benefit — while noting that a non-vented seal used with reassessment, burping and decompression has not been shown to do worse in people.17

▾Does a vent prevent tension pneumothorax?

It is designed to let air out, which makes pressure less likely to build — but no vent is a guarantee. Vents can clog with blood or be blocked by the casualty's body weight.4,11 Every casualty with a chest seal is watched for worsening breathing, and the seal is burped or removed if breathing gets worse.1

▾How do I burp a chest seal?

Lift one edge with the pull tab so trapped air and blood can escape, then press the edge back down — or take the seal off. If breathing does not improve, trained providers follow the TCCC Guidelines' decompression direction.1,4

▾Will it stick to a sweaty, hairy or bloody chest?

Medical Devices, Inc. states the HALO Vent adheres in damp, sandy and hairy conditions and in the presence of blood or pleural fluid, using hydrogel plus an outer tape edge.3,4 Seals lifting off the skin is still a documented failure in testing,11,13 so wipe the skin dry first and press the edges down firmly.

▾Why two seals in one pack?

Penetrating wounds often have an exit, and the instructions direct a second seal on any additional chest wound.4 Roll the casualty or run your hands down the back and sides — the back is where exit wounds hide.

▾What if I don't have a chest seal?

Most bystanders won't. Have the casualty press their own hand over the hole, or cover it the best way you can, and keep watching their breathing. Improvising a seal is hard unless you have tape and something airtight: in a pig chest-wall model, wet rescue-blanket squares sealed every test wound while foil from a gauze wrapper sealed none.18 Unconscious and breathing: recovery position. Conscious: let them sit up or find the position that eases their breathing.1

▾Should EMS use a chest seal on a patient being bagged?

The NAEMSP 2024 position statement advises that EMS clinicians may consider a vented seal for a spontaneously breathing patient with an open pneumothorax, but that chest seals may be harmful and are not recommended during positive-pressure ventilation.16 Follow your agency's protocol.

▾Can I pack a chest wound?

No. Never pack gauze into the chest or the abdomen. A chest wound gets a seal; bleeding from it is controlled with direct pressure over and around the wound while you get the seal on.

▾How should I store it, and how long does it last?

Store it sealed in its pouch within −30 °F to 140 °F (−34 °C to 60 °C). Shelf life is six years.3,7 It is non-sterile and single use — replace it once the pouch has been opened.4,7

Package & specifications

▾In the package — two vented seals
  • 2× HALO™ Vent vented chest seal, 8.35 × 6.06 in. (21.2 × 15.4 cm), folded in thirds — transparent, scrim-reinforced hydrogel with an outer tape edge, four vents, large pull tab
  • 1× IFAK pouch, 5.5 × 7.5 in. (14 × 19 cm), tear notches for opening
  • Non-sterile, single use, latex-free. Gloves sold separately.
▾Full specifications
Specification Detail
Manufacturer Medical Devices, Inc. — Romulus, Michigan, USA
Product HALO™ Vent, 2 HALO Vent IFAK
Manufacturer item US 1216-10020
Contents 2 HALO Vent vented chest seals in one IFAK pouch
Seal size 8.35 × 6.06 in. (21.2 × 15.4 cm)
Pouch 5.5 × 7.5 in. (14 × 19 cm), IFAK size; seals folded in thirds
Vent Hydrogel-free center over the wound; four vents around the dressing; valve material moves with small pressure changes
Adhesive Hydrogel infused with scrim, plus an outer tape edge
Backing Transparent; oversized release liner; large pull tab
Temperature rating −30 °F to 140 °F (−34 °C to 60 °C) — storage and handling
Shelf life 6 years
Latex Latex-free — not made with natural rubber latex
Sterility / use Non-sterile, single use
Contraindication (manufacturer) Post-surgical applications
FDA Occlusive wound dressing, product code NAD, 21 CFR 878.4020 — FDA-registered, Class I (510(k)-exempt)
Patent U.S. RE48,007
Made in USA
TCCC status Vented chest seal — the device type the TCCC Guidelines call for first; not evidence-based standard (the evidence-based list names no chest seal)
▾References — 18 sources
  1. Committee on Tactical Combat Casualty Care. Tactical Combat Casualty Care (TCCC) Guidelines, 1 May 2026.
  2. Committee on Tactical Combat Casualty Care. Evidence-Based Standard Devices & Adjuncts, 15 December 2021.
  3. Medical Devices, Inc. 2 HALO Vent IFAK (US 1216-10020) — specifications, product features and intended use. medicaldevicesinc.com (WEB-038 rev04, effective 27 February 2026).
  4. Medical Devices, Inc. HALO Vent Instructions for Use, United States. Doc. MAW-0430 rev04.
  5. Medical Devices, Inc. Company history and product FAQ — IFAK and Flat Pack pouches, HALO dimensions, ISO 13485, U.S. manufacturing. medicaldevicesinc.com.
  6. U.S. Food and Drug Administration. Establishment Registration & Device Listing — Medical Devices Inc., Romulus, MI: Halo Seal, Halo Vent, Halo XL; product code NAD (Dressing, Wound, Occlusive), 21 CFR 878.4020, Class I, 510(k)-exempt.
  7. U.S. National Library of Medicine. AccessGUDID device record — Halo, US 1216-10020 (Halo Vent 2 Pack IFAK), primary DI 00850010608280.
  8. Shulman S, Shulman S, Azziz J; Medical Devices, Inc. Vented emergency wound dressings. U.S. Patent RE48,007 E, reissued 26 May 2020.
  9. Butler FK Jr, DuBose JJ, Otten EJ, et al. Management of open pneumothorax in Tactical Combat Casualty Care: TCCC Guidelines Change 13-02. J Spec Oper Med. 2013;13(3):81–86.
  10. Kheirabadi BS, Terrazas IB, Koller A, et al. Vented versus unvented chest seals for treatment of pneumothorax and prevention of tension pneumothorax in a swine model. J Trauma Acute Care Surg. 2013;75(1):150–156.
  11. Kheirabadi BS, Terrazas IB, Miranda N, et al. Do vented chest seals differ in efficacy? An experimental evaluation using a swine hemopneumothorax model. J Trauma Acute Care Surg. 2017;83(1):182–189.
  12. Kotora JG Jr, Henao J, Littlejohn LF, Kircher S. Vented chest seals for prevention of tension pneumothorax in a communicating pneumothorax. J Emerg Med. 2013;45(5):686–694.
  13. Arnaud F, Maudlin-Jeronimo E, Higgins A, et al. Adherence evaluation of vented chest seals in a swine skin model. Injury. 2016;47(10):2097–2104.
  14. Paquette R, Quinene M, Blackbourne LH, Allen PB. Efficacy of commercial chest seal adherence and tension pneumothorax prevention: a systematic review of quantitative studies. J Spec Oper Med. 2021;21(3):78–85.
  15. Schauer SG, April MD, Naylor JF, et al. Chest seal placement for penetrating chest wounds by prehospital ground forces in Afghanistan. J Spec Oper Med. 2017;17(3):85–89.
  16. Lyng JW, Ward C, Angelidis M, et al. Prehospital Trauma Compendium: traumatic pneumothorax care — position statement and resource document of NAEMSP. Prehosp Emerg Care. Published online 4 December 2024.
  17. Margolis AM, Tang N, Levy MJ, Callaway DW. Management of open chest wounds in tactical emergency casualty care: application of vented versus nonvented chest seals. J Spec Oper Med. 2014;14(4):136–138.
  18. Schachner T, Isser M, Haselbacher M, et al. Rescue blanket as a provisional seal for penetrating chest wounds in a new ex vivo porcine model. Ann Thorac Surg. 2022;114(1):280–285.
Genuine HALO™ — Medical Devices, Inc.
Sourced direct from the manufacturer or an authorized master distributor. Ships from MED-TAC International, South Florida, US of A — clinician-founded, veteran-led, SDVOSB-certified.
SPECS & MEASUREMENTS

Specifications coming soon. Contact us for detailed product information.

CLINICAL RATIONALE

Chest Seals in Thoracic Trauma

Chest seals are critical life-saving tools for treating open chest wounds (sucking chest wounds) that disrupt the negative pressure needed for normal breathing.
When air enters the pleural space through a penetrating injury, it prevents the lung from fully expanding and may lead to a tension pneumothorax — a life-threatening condition if not addressed promptly.
Properly applied chest seals restore intrathoracic pressure balance and allow the injured lung to re-expand, buying vital time until definitive care or decompression is available.

1. Vented Chest Seals

Clinical Rationale (Vented):

Vented chest seals feature one-way valves or channels that allow trapped air and fluids to escape from the chest cavity while preventing further air entry.
This controlled venting mechanism reduces the risk of developing a tension pneumothorax and is recommended by the Committee on Tactical Combat Casualty Care (CoTCCC) for most open thoracic injuries when the vent remains unobstructed.
In tactical and emergency medical settings, vented seals maintain proper intrathoracic pressure dynamics and help stabilize respiration during evacuation.

  • Allows air and blood to escape while blocking additional air entry
  • Recommended by CoTCCC for most penetrating chest wounds
  • Prevents progression to tension pneumothorax
  • Effective during movement and transport phases

2. Non-Vented Chest Seals

Clinical Rationale (Non-Vented):

Non-vented chest seals provide a fully occlusive barrier that prevents any external air from entering the pleural cavity.
These are preferred when environmental factors — such as dust, debris, heavy clothing, or complex wound locations — could obstruct a vent or prevent it from functioning properly.
Non-vented models are especially effective when there are multiple wounds or when both sides of the chest are compromised.

  • Creates an airtight seal to stop further air intrusion
  • Ideal for contaminated or complex wound environments
  • Preferred for posterior or multiple thoracic injuries
  • Simple and reliable under stress conditions

3. Twin Pack / Dual Application

Clinical Rationale (Twin Pack):

Twin chest seal packs are designed for simultaneous coverage of entry and exit wounds or multiple penetrating thoracic injuries.
Applying seals to both anterior and posterior wounds prevents air intrusion from either side and ensures consistent intrathoracic pressure stabilization.
This configuration allows medics and responders to treat through-and-through injuries quickly and efficiently without improvisation.

  • Enables rapid treatment of entry and exit wounds
  • Maintains consistent chest pressure across both sides
  • Optimized for tactical and prehospital trauma management
  • Reduces need for multiple packages or improvised seals

4. Training Chest Seals

Clinical Rationale (Training):

Training chest seals replicate the adhesive strength and venting design of operational models using non-sterile materials.
They are intended for classroom, simulation, and scenario-based instruction, allowing responders to practice correct placement, adhesion, and vent inspection without wasting live medical gear.
Consistent repetition with realistic trainers develops muscle memory and speed during actual trauma incidents.

  • Simulates vented or occlusive seal behavior for realistic training
  • Promotes correct placement and adhesion technique
  • Preserves sterile operational supplies
  • Ideal for EMT, tactical, and civilian responder courses

Clinical Summary

Chest seals play a pivotal role in preventing death from tension pneumothorax, one of the leading causes of preventable trauma mortality.
Both vented and non-vented designs serve distinct operational needs, while twin and training packs ensure preparedness across all care phases — from education to battlefield or civilian emergencies.

  • Vented: Allows controlled egress of trapped air; standard CoTCCC-recommended choice.
  • Non-Vented: Fully occlusive; best for debris-rich or posterior wound sites.
  • Twin Pack: Provides coverage for through-and-through injuries.
  • Training: Non-sterile practice tool for skill retention and readiness.

By re-establishing chest wall integrity and controlling air movement, chest seals restore lung expansion and stabilize respiratory mechanics until advanced medical care is available.

SHIPPING & RETURNS

Domestic & Military Shipping

Free Standard Shipping: Automatically applied at checkout on all orders $200 and above within the 48 contiguous United States (CONUS).

APO/FPO Military Addresses: Unconditionally free standard shipping on every order, with no minimum purchase required.

Order Processing & Tracking

Fulfillment Timeline: In stock merchandise ships within 48-72 hours from Florida HQ.

Automated carrier tracking details are emailed immediately upon shipment dispatch.

30-Day Returns & Medical Safety

Returns: Unused, unopened equipment in original manufacturer packaging is eligible for return within 30 days of delivery.

Bio-Safety Notice: To ensure sterility and patient safety, medical consumables with opened or broken tamper-evident seals cannot be returned.

Return Facility: MED-TAC International Corp., 15757 Pines Blvd, Suite 154, Pembroke Pines, FL 33027.

Export Compliance

North American Rescue (NAR) products and rifle hard armor plates are strictly restricted to US and APO/FPO addresses and cannot be exported internationally.

FREQUENTLY ASKED QUESTIONS

Customer Reviews

Shopping cart

Your cart is empty.

Return to shop
Link copied to clipboard