0
Free US Shipping $200+  •  APO/FPO Always Ships Free Shop All →
Free US Shipping $200+ • APO/FPO Always Free ★ SDVOSB • CAGE: 9VFL3 • Medical SME-Led

Abdominal Aortic and Junctional Tourniquet – Stabilized (AAJT-S)

$489.95
Request a custom quote for bulk orders, agency procurement, or government purchases
FREE APO/FPO SHIPPING • EVERY ORDER • NO MINIMUM

Guaranteed duty-free priority delivery to all deployed military postal codes worldwide.

Ships from Florida HQ Free Shipping $200+ CONUS Free APO/FPO Shipping 30-Day Unopened Returns
Fulfillment Timeline: In stock merchandise ships within 48-72 hours from Florida HQ.
$489.95
PRODUCT INFORMATION
Compression Works · Junctional & Abdominal Aortic Tourniquet
Abdominal Aortic and Junctional Tourniquet – Stabilized (AAJT-S)
A wedge-shaped bladder on a ratcheting belt, inflated by hand pump until its gauge shows green. On the groin or the armpit it compresses the artery at that junction; over the navel it compresses the descending aorta, cutting blood flow to the pelvis and both legs. FDA-cleared to control bleeding in the pelvis, inguinal area and axilla, and for pelvic fracture stabilization.
FDA-cleared · K221661Groin · armpit · abdomen · pelvis1 h abdominal · 4 h junctionalBleed-off below 300 mmHgNSN 6515-01-695-4457

Abdominal placement shuts off arterial flow to the pelvis and both legs — which is why it runs on a one-hour clock and carries two contraindications you check before you inflate.

The short answer
What it is
A pneumatic junctional and abdominal aortic tourniquet: a wedge-shaped bladder, ladder strap and ratcheting buckle, hand pump and pressure gauge, with a bleed-off that keeps the bladder under 300 mmHg.
Use it for
Groin or armpit bleeding a limb tourniquet cannot control; pelvic and both-leg bleeding through the abdominal placement; pelvic fracture stabilization.
How it's used
Pack and press while it is readied. Connect red to red, set the bladder over the target, pull out all slack, ratchet tight, then inflate until the gauge shows green.
Who carries it
Combat and tactical medics, EMS systems with an AAJT-S protocol, flight and critical-care transport teams, and emergency departments — a device for trained, credentialed providers.

At a glance

Cleared for
Pelvic, groin and armpit bleeding; pelvic fracture
FDA
510(k) K221661
Mechanism
Pneumatic wedge bladder
Inflate to
Green on the gauge
Over-pressure
Bleed-off below 300 mmHg
Labeled time
4 h groin/armpit · 1 h abdomen
Weight
25 oz
Packaged size
9 × 8 × 2 in.
NSN
6515-01-695-4457
Manufacturer item
AAJT-S001 · NAR 30-0248

12 things to know about the AAJT-S

Where it goes, the clock and the contraindications, and what the volunteer, swine and case evidence shows.

  1. 01

    Four uses from one belt

    The FDA cleared the AAJT-S to control bleeding in the pelvis, inguinal area and axilla, and for pelvic fracture stabilization.4 Placement decides the job: over the navel for pelvic or both-leg bleeding, over the affected groin for one leg, over the armpit for the arm, and around the hips — uninflated — to stabilize the pelvis.6,7

  2. 02

    Abdominal placement compresses the aorta

    Inflated over the lower abdomen, the wedge bladder pushes in on everything beneath it, including the descending aorta at or near the point where it divides into the iliac arteries.4,6 That shuts off arterial flow to the pelvis and both legs at once — which is also why the abdominal placement runs on a shorter clock.

  3. 03

    One hour on the abdomen, four at a junction

    The AAJT-S is labeled for up to 1 hour in the abdominal position and up to 4 hours at the groin or armpit.4,6 In survival swine, a 1-hour abdominal application was followed by full recovery of leg function within a week, while 2 hours produced lasting hind-leg paralysis; the investigators concluded abdominal use should not exceed 1 hour.15

  4. 04

    Two contraindications — abdominal placement only

    Do not place it on the abdomen with a known abdominal aortic aneurysm or in pregnancy. The instructions list no contraindications for groin or armpit placement.6

  5. 05

    Tight before you inflate

    Connect the ladder strap red to red, pull out all slack and finish with the ratcheting buckle. The tighter the belt before inflation, the more stable and effective the device, and the lower the bladder volume needed to compress the artery — faster and less painful.6 The ratchet replaced the original AAJT's windlass so the belt can be tightened with one hand.4

  6. 06

    Inflate to green

    Pump until the gauge shows green — the mark the instructions tie to 250 mmHg — and a bleed-off design keeps the bladder under 300 mmHg, including when altitude changes.6 Compression Works cites human studies in which flow stopped at 230 mmHg.6 For pelvic stabilization the bladder is not inflated.7

  7. 07

    It hurts, and it affects breathing

    In nine volunteers, the earlier abdominal tourniquet stopped femoral flow in seven at a median 180 mmHg, with a median discomfort score of 7 out of 10.11 In spontaneously breathing swine with the earlier AAJT held on the abdomen for 2 hours, breathing became labored and stopped when the device was released, and three of six animals died after blood flow returned.14

  8. 08

    Removal is a hospital decision

    The instructions warn that removal may lead to resumed bleeding.6 Compression Works directs: never cut it off; deflate slowly while watching the casualty, then release the pull tab and the strap — and if bleeding returns, re-engage the strap and re-inflate.7 A 2026 case report describes cardiac arrest, compartment syndrome, rhabdomyolysis, organ infarcts, pulmonary emboli and stroke after removal in a trauma bay.21

  9. 09

    What the S changed

    The AAJT-S replaced the original AAJT's windlass with a ladder strap and ratcheting buckle, moved tightening to the front, added a D-handle for gloved hands, widened the belt, made the cover one continuous piece of HDPE plastic, and added the pelvic stabilization indication.4 Field testing of the original found durability problems: in Israeli Defense Forces medic testing, all three original AAJT units had broken by the fifth tester.18 The AAJT-S carries its own NSN, 6515-01-695-4457.8,10

  10. 10

    Packing and pressure come first while it's readied

    The TCCC Guidelines direct a junctional tourniquet immediately when the bleeding site is amenable to one, with no delay once it is ready — and hemostatic dressings with direct pressure if a junctional tourniquet is not available or while it is being readied.1 The same guidelines list XStat as best for deep, narrow-tract junctional wounds.1

  11. 11

    What volunteers and swine show

    In 16 UK soldiers, the earlier abdominal tourniquet eliminated femoral flow in 15.12 At the groin and armpit, the AAJT stopped flow in all 13 volunteers in its FDA submission.5 UK combat medical technicians applied the AAJT-S successfully in 27 of 34 attempts after one hour of training, in a median 75 seconds in daylight and 57 in low light.13 In swine, the AAJT and zone 3 REBOA — a balloon passed into the aorta — achieved similar bleeding control.16,17

  12. 12

    The evidence base is still thin

    A 2025 systematic review found 14 studies — swine, healthy volunteers, one case report and one manikin study — no randomized trials and an overall low evidence base, with ischemia-reperfusion injury tied to how long the device stayed on.20 Case series in traumatic cardiac arrest point both ways: no survivors to hospital discharge in a Sydney physician-led service,22 and return of circulation in all six casualties at a Ukrainian forward surgical site.23 Compression Works notes that published cases may describe uses outside the FDA-cleared indications.7

How to apply the AAJT-S

Compression Works' five application steps, with the TCCC step before them and the checks after.

  1. 1
    Control it by hand first. Pack the wound with hemostatic gauze and hold firm direct pressure while a teammate readies the AAJT-S.1
  2. 2
    Pick the site. Abdomen over the navel for pelvic or both-leg bleeding, the affected groin, or the armpit. Before an abdominal placement, rule out the contraindications: known abdominal aortic aneurysm or pregnancy.6
  3. 3
    Connect red to red. Secure the belt around the waist, the hips or the shoulder and connect the ladder strap until the red marks meet.6
  4. 4
    Position the bladder. Set it directly over the target: the navel, the affected groin or the armpit.6
  5. 5
    Remove all slack. Pull the strap hard — the device must be very tight before inflation.6
  6. 6
    Ratchet. Use the ratcheting buckle to complete the tightening.6
  7. 7
    Inflate to green. Pump until the gauge shows green. For pelvic stabilization alone, do not inflate.6,7
  8. 8
    Record the time. Write down the inflation time — the clock is 1 hour on the abdomen and 4 hours at the groin or armpit.1,6
  9. 9
    Reassess and hand it off. Watch the bleeding, the breathing and the gauge through transport. Never cut it off; deflation and removal belong to the receiving clinicians.6,7
Train on a trainer. An AAJT-S trainer is made for practice;24 the live device is single use and stays with the casualty through the hand-off.7,9 It ships ready to use in sealed packaging — while the seal is intact no field check is needed. If the package is damaged, inspect the belt, buckle, ladder strap and tubing, then inflate to green and wait 5 minutes; if the green drops out of view, do not use it.6

Where it fits

Use it for
  • Groin bleeding a limb tourniquet cannot control
  • Armpit bleeding
  • Pelvic and both-leg bleeding through the abdominal placement — up to 1 hour
  • Pelvic fracture stabilization, uninflated around the hips
Not for
  • Abdominal placement in pregnancy or with a known abdominal aortic aneurysm6
  • Abdominal use beyond 1 hour, or junctional use beyond 4 hours6
  • Limb bleeding a tourniquet can control — limb tourniquet first1
  • Cutting it off to remove it — deflate and release instead7
  • Providers without device-specific training

The evidence

Every study cited above, what it tested, and how strong the evidence is.

Study Evidence type What was studied What it found
Lyon et al., J Trauma Acute Care Surg 2012 Human · volunteers Earlier Abdominal Aortic Tourniquet over the lower abdomen, 9 volunteers Femoral flow stopped in 7 of 9 at a median 180 mmHg; median discomfort 7/10, gone after removal
Taylor et al., Mil Med 2013 Human · volunteers Earlier Abdominal Aortic Tourniquet, 16 UK soldiers Femoral flow eliminated in 15 of 16; all tolerated it
FDA 510(k) K133029 summary, 2013 Human · volunteers AAJT at the groin and the armpit, 13 volunteers Flow stopped at both sites in 13 of 13; mean bladder pressure 149 and 168 mmHg
Smith TN et al., BMJ Mil Health 2023 Human · volunteers AAJT-S applied by 17 UK combat medical technicians to one another, 34 applications 79% successful; median 75 s in daylight, 57 s in low light
Chen et al., J Spec Oper Med 2016 Human · medic testing CRoC, AAJT, JETT and SAM Junctional Tourniquet tested by 14 Israeli Defense Forces medics All three original AAJT units broken by the fifth tester; top models did not differ significantly
Kheirabadi et al., Shock 2016 Animal · swine Earlier AAJT on the abdomen for 2 hours to control groin bleeding, 18 swine Bleeding controlled; spontaneous breathers stopped breathing at release; 3 of 6 died after reflow
Kheirabadi et al., J Surg Res 2018 Animal · survival swine Abdominal AAJT for 1, 1.5 or 2 hours, followed up to 2 weeks 1 h: full recovery; 2 h: lasting paraplegia; abdominal use should not exceed 1 h
Rall et al., J Surg Res 2018 Animal · randomized swine AAJT vs zone 3 REBOA, femoral artery bleeding, 10 swine Both 100% hemostasis; AAJT had higher blood pressure and lactate
Schechtman et al., J Trauma Acute Care Surg 2020 Animal · swine AAJT vs zone 3 REBOA for 60 minutes, 20 swine in severe shock Similar bleeding control; transiently lower blood pressure after AAJT deflation
Smith S et al., J Trauma Acute Care Surg 2019 Expert review · meta-analysis Eight healthy-volunteer studies of four junctional devices Abdominal AAJT 52% average effectiveness; groin placement 100% in 2 studies
Webster et al., BMJ Mil Health 2025 Expert review · systematic review Evidence for the AAJT-S in combat care, 14 studies No randomized trials; overall low evidence; ischemia-reperfusion injury dependent on duration
Balian et al., Resuscitation 2020 Human · case series AAJT in prehospital traumatic cardiac arrest, physician-led service, Sydney Physiological changes and some return of circulation; no survivors to hospital discharge
Androshchuk & Verba, J Spec Oper Med 2025 Human · case series AAJT-S in 6 casualties in traumatic cardiac arrest, forward surgical site, Ukraine All 6 resuscitated; 4 survived to discharge
Gerstner et al., Prehosp Emerg Care 2026 Human · case report Young adult with pelvic and leg gunshot wounds arriving with an AAJT-S in place Cardiac arrest after removal, then multi-organ complications; authors urge caution

Strongest to weakest: human studies, then animal studies. The human data are healthy volunteers and small case series, several on the earlier AAT and AAJT models; no trial has measured survival. The swine studies show both the hemostatic effect and the time-dependent cost of compressing the aorta.

How it compares

The four FDA-cleared junctional devices a buyer weighs, side by side.

AAJT-S SAM Junctional Tourniquet JETT CRoC
Mechanism Hand-pumped wedge bladder on a ratcheting belt Hand-pumped target compression device on a force-limiting belt Two screw-down pressure pads on a belt Aluminum clamp with a screw-down pressure disc
FDA-cleared for Bleeding in the pelvis, inguinal area and axilla; pelvic fracture stabilization Inguinal and axillary bleeding; pelvic fracture immobilization Inguinal bleeding Inguinal and axillary bleeding; last resort for carotid bleeding
Both groins from one device Abdominal placement stops flow to both legs Yes — the JT400-EN kit carries two compression devices Yes — two pads No — one clamp per side
Labeled maximum 4 h groin or armpit · 1 h abdomen 4 h 4 h 4 h
Weight 25 oz 24 oz (JT400-EN) 1 lb 8 oz 1.25 lb
Volunteer effectiveness (meta-analysis) Earlier AAJT: 52% abdominal; groin 100% in 2 studies 87% 83% 95%
Mean application time (meta-analysis) Earlier AAJT, abdominal: 92 s and 171 s 101 s 130 s 101 s
Named on the 2019 evidence-based list No Yes Yes Yes
evidence-based standard today No — the current list names no junctional device No — the current list names no junctional device No — the current list names no junctional device No — the current list names no junctional device

Indications and labeled times come from each device's FDA 510(k) record and instructions;4,6,25,26,27 weights from published specifications;8,25,26,27 effectiveness and application times are averages from healthy-volunteer studies, which tested the earlier AAJT, not the AAJT-S.19 The current evidence-based list names no junctional product at all;2 absence from it does not by itself mean a device was tested and failed.

Build the system

The packing that goes in first, the other junctional options, a dedicated pelvic binder and the training aid.

Free from MED-TAC
The Trauma Brief
MED-TAC's free trauma field guide, written by a physician and medical educator — what to do in the first minutes of a severe bleed, step by step.
Get the Brief ›

Questions buyers ask

▾Is the AAJT-S evidence-based standard?

No. The 2019 Evidence-Based Standard Devices list named three junctional devices — the CRoC, SAM-JT and JETT — and not the AAJT.3 The current list, dated 15 December 2021, names no specific junctional product and leaves the choice to any FDA-cleared device indicated for junctional hemorrhage control;2 the AAJT-S, cleared for groin and armpit bleeding, meets that criterion.4

▾When is the abdominal placement used?

For bleeding in the pelvis or in both legs — the indications the instructions pair with placement over the navel.6 It compresses the aorta, so it is limited to 1 hour and is contraindicated in pregnancy or with a known abdominal aortic aneurysm.4,6

▾Can it be used on a pregnant casualty?

Not on the abdomen — pregnancy is a contraindication for abdominal placement. The instructions list no contraindications for groin or armpit placement.6

▾How long can it stay on?

Up to 1 hour on the abdomen and up to 4 hours at the groin or armpit.4,6 Record the inflation time when it goes on.1

▾How much pressure does it use?

Inflate until the gauge shows green, the 250 mmHg mark; a bleed-off keeps the bladder under 300 mmHg even with altitude change. A tight belt before inflation means less bladder volume and less pain.6

▾Should I pack the wound first?

Yes, while the AAJT-S is being readied — the TCCC Guidelines call for hemostatic dressings with direct pressure until the junctional tourniquet is ready, then immediate application.1

▾How is it removed?

By the receiving clinicians, never by cutting. The bladder is deflated slowly while the casualty is monitored, then the pull tab and strap are released; removal may bring the bleeding back, and the strap can be re-engaged and the bladder re-inflated.6,7

▾Does it work as a pelvic binder?

Yes — pelvic fracture stabilization is a cleared indication. Place it around the hips, centered over the pelvis, tighten it, and do not inflate the bladder.4,6,7

▾Has it been used in the armpit on real casualties?

Yes. The first reported human use of a junctional tourniquet for armpit bleeding was the AAJT's predecessor, off-label in 2013, reported by the device's inventor, who also reported a groin gunshot case.28 Armpit bleeding is now a cleared indication.4

▾How do I store and check it?

Leave it in its sealed package — while the seal is intact, no field check is needed. If the package is damaged, inspect the belt (do not use it with a cut longer than 2 mm), the buckle, the ladder strap and the tubing, then inflate to green for 5 minutes; if the green drops out of view, do not use it.6

▾Is it reusable? Is there a trainer?

The AAJT-S is single use and stays with the casualty through the hand-off.7,9 An AAJT-S trainer is made for practice.24

Package & specifications

▾In the package — one device, sealed
  • 1× AAJT-S belt with wedge-shaped bladder, ladder strap, ratcheting buckle and D-handle — Compression Works model AAJT-S001
  • Hand pump and tubing with integrated pressure gauge, bleed-off and deflation valve
  • Instructions for use
  • Sealed, ready-to-use packaging. Non-sterile, single use.
▾Full specifications
Specification Detail
Manufacturer Compression Works, Inc. — Birmingham, Alabama
Product Abdominal Aortic and Junctional Tourniquet – Stabilized (AAJT-S)
Manufacturer model AAJT-S001
Distributor item North American Rescue 30-0248
NSN 6515-01-695-4457
GTIN (UDI-DI) 00860002227504
FDA 510(k) K221661, cleared 3 March 2023 — Class II, product code DXC (vascular clamp). Predecessors: AAJT K133029 (2013); Abdominal Aortic Tourniquet K112384 (2011)
Cleared indications To control bleeding in the pelvis, inguinal area, axilla and for pelvic fracture stabilization
Labeled time Up to 1 hour abdominal; up to 4 hours junctional (groin or axilla)
Contraindications Abdominal placement: known abdominal aortic aneurysm; pregnancy. None listed for groin or armpit placement
Mechanism Wedge-shaped pneumatic bladder; ladder strap and ratcheting buckle; D-handle; hand pump; pressure gauge
Inflation To the green indicator (250 mmHg check point); bleed-off keeps pressure under 300 mmHg
Weight 25 oz
Dimensions Packaged 9 × 8 × 2 in.; stored 7.5 × 6.5 × 2 in.
Packaging Sealed, ready to use
Sterility / use Non-sterile, single use; stays with the casualty
Origin Manufactured in USA
Clinical evaluation Not named on the 2019 list; the current Evidence-Based Standard Devices list (15 Dec 2021) names no specific junctional device
▾References — 28 sources
  1. Committee on Tactical Combat Casualty Care. Tactical Combat Casualty Care (TCCC) Guidelines, 1 May 2026.
  2. Committee on Tactical Combat Casualty Care. Evidence-Based Standard Devices & Adjuncts, 15 December 2021.
  3. Committee on Tactical Combat Casualty Care. Evidence-Based Standard Devices & Adjuncts, 1 August 2019 (Junctional Tourniquets & Devices: CRoC, SAM-JT, JETT).
  4. U.S. Food and Drug Administration. 510(k) K221661, Abdominal Aortic and Junctional Tourniquet – Stabilized (AAJT-S), Compression Works, cleared 3 March 2023 — indications for use and 510(k) summary.
  5. U.S. Food and Drug Administration. 510(k) K133029, Abdominal Aortic and Junctional Tourniquet (AAJT), cleared 6 December 2013, and K112384, Abdominal Aortic Tourniquet, cleared 18 October 2011 — 510(k) summaries.
  6. Compression Works. Abdominal Aortic & Junctional Tourniquet (Stabilized) AAJT-S Instructions for Use, US rev 002 (28 February 2022).
  7. Compression Works. AAJT-S product, training and protocol pages, and AAJT-S Application & Removal Guide (2026).
  8. North American Rescue. AAJT-S product information sheet, item 30-0248 (REV101625).
  9. National Library of Medicine. AccessGUDID device record 00860002227504, Abdominal Aortic & Junctional Tourniquet (Stabilized) – AAJT-S, model AAJT-S001.
  10. Defense Logistics Agency. Federal Logistics Information System record, NSN 6515-01-695-4457 (abdominal aortic and junctional tourniquet-stabilized, AAJT-S001).
  11. Lyon M, Shiver SA, Greenfield EM, et al. Use of a novel abdominal aortic tourniquet to reduce or eliminate flow in the common femoral artery in human subjects. J Trauma Acute Care Surg. 2012;73(2 Suppl 1):S103–S105.
  12. Taylor DM, Coleman M, Parker PJ. The evaluation of an abdominal aortic tourniquet for the control of pelvic and lower limb hemorrhage. Mil Med. 2013;178(11):1196–1201.
  13. Smith TN, Beaven A, Handford C, Sellon E, Parker PJ. Abdominal Aortic Junctional Tourniquet – Stabilized (AAJTS) can be applied both successfully and rapidly by Combat Medical Technicians (CMTs). BMJ Mil Health. 2023;169(6):493–498.
  14. Kheirabadi BS, Terrazas IB, Miranda N, et al. Physiological consequences of Abdominal Aortic and Junctional Tourniquet (AAJT) application to control hemorrhage in a swine model. Shock. 2016;46(3 Suppl 1):160–166.
  15. Kheirabadi BS, Terrazas IB, Miranda N, et al. Long-term consequences of abdominal aortic and junctional tourniquet for hemorrhage control. J Surg Res. 2018;231:99–108.
  16. Rall JM, Redman TT, Ross EM, Morrison JJ, Maddry JK. Comparison of zone 3 Resuscitative Endovascular Balloon Occlusion of the Aorta and the Abdominal Aortic and Junctional Tourniquet in a model of junctional hemorrhage in swine. J Surg Res. 2018;226:31–39.
  17. Schechtman DW, Kauvar DS, De Guzman R, et al. Abdominal aortic and junctional tourniquet versus zone III resuscitative endovascular balloon occlusion of the aorta in a swine junctional hemorrhage model. J Trauma Acute Care Surg. 2020;88(2):292–297.
  18. Chen J, Benov A, Nadler R, et al. Testing of junctional tourniquets by medics of the Israeli Defense Force in control of simulated groin hemorrhage. J Spec Oper Med. 2016;16(1):36–42.
  19. Smith S, White J, Wanis KN, et al. The effectiveness of junctional tourniquets: a systematic review and meta-analysis. J Trauma Acute Care Surg. 2019;86(3):532–539.
  20. Webster S, Ritson JE, Barnard EBG. Abdominal aortic junctional tourniquet (AAJT-S): a systematic review of utility in military practice. BMJ Mil Health. 2025;171(3):262–268.
  21. Gerstner G, Rizzo J, Kieffer C, Lowe J. Between hemorrhage and harm: complications of the Abdominal Aortic and Junctional Tourniquet-Stabilized. Prehosp Emerg Care. 2026 (published online 10 September 2026).
  22. Balian F, Garner AA, Weatherall A, Lee A. First experience with the abdominal aortic and junctional tourniquet in prehospital traumatic cardiac arrest. Resuscitation. 2020;156:210–214.
  23. Androshchuk D, Verba A. Successful management of battlefield traumatic cardiac arrest using the Abdominal Aortic and Junctional Tourniquet (AAJT): a case series. J Spec Oper Med. 2025;25(1):65–69.
  24. Bound Tree Medical. Abdominal Aortic and Junctional Tourniquet (AAJT-S), Trainer — Compression Works, item 97-1220-00248.
  25. U.S. Food and Drug Administration. 510(k) K123694 (7 March 2013) and K131561 (24 July 2013), SAM Junctional Tourniquet; SAM Medical, SJT product specification sheet SJT-SS-05 and Instructions for Use JT-IS-EN-05.
  26. U.S. Food and Drug Administration. 510(k) K123194, Junctional Emergency Treatment Tool, North American Rescue, cleared 3 January 2013; North American Rescue, JETT Instructions for Use ZZ-0450 and product information sheet, item 30-0088.
  27. U.S. Food and Drug Administration. 510(k) K130482 (29 April 2013) and K141685 (26 January 2015), Combat Ready Clamp (CRoC), Combat Medical Systems — indications, 4-hour use, 1.25 lb with disc.
  28. Croushorn J, McLester J, Thomas G, McCord SR. Abdominal aortic tourniquet controls junctional hemorrhage from a gunshot wound of the axilla. J Spec Oper Med. 2013;13(3):1–4; Croushorn J. Abdominal aortic and junctional tourniquet controls hemorrhage from a gunshot wound of the left groin. J Spec Oper Med. 2014;14(2):6–8.
Genuine Compression Works
Sourced direct from the manufacturer or an authorized master distributor. Ships from MED-TAC International, South Florida, US of A — clinician-founded, veteran-led, SDVOSB-certified.
SPECS & MEASUREMENTS

Specifications coming soon. Contact us for detailed product information.

SHIPPING & RETURNS

Domestic & Military Shipping

Free Standard Shipping: Automatically applied at checkout on all orders $200 and above within the 48 contiguous United States (CONUS).

APO/FPO Military Addresses: Unconditionally free standard shipping on every order, with no minimum purchase required.

Order Processing & Tracking

Fulfillment Timeline: In stock merchandise ships within 48-72 hours from Florida HQ.

Automated carrier tracking details are emailed immediately upon shipment dispatch.

30-Day Returns & Medical Safety

Returns: Unused, unopened equipment in original manufacturer packaging is eligible for return within 30 days of delivery.

Bio-Safety Notice: To ensure sterility and patient safety, medical consumables with opened or broken tamper-evident seals cannot be returned.

Return Facility: MED-TAC International Corp., 15757 Pines Blvd, Suite 154, Pembroke Pines, FL 33027.

Export Compliance

North American Rescue (NAR) products and rifle hard armor plates are strictly restricted to US and APO/FPO addresses and cannot be exported internationally.

FREQUENTLY ASKED QUESTIONS

Customer Reviews

Shopping cart

Your cart is empty.

Return to shop
Link copied to clipboard