The Wide answers the one question every compact tourniquet gets asked — is the band wide enough — without giving up the size that gets it carried.
At a glance
12 things to know about the ETQ Gen 2 Wide
Why the wider band exists, what the Gen 2 changes do, and what the record of real uses shows.
-
01
The full 1.5 in. does the constricting
Snakestaff built the Wide with a 1.5 in. constricting band for applications where a wider tourniquet is wanted.3 How pressure spreads across a tourniquet's width is one of the factors that sets how much pressure it takes to stop arterial flow.8 On the C-A-T®, a free-moving internal band inside the 1.5 in. strap does the tightening — researchers measure it at 2.5 cm.7,8
-
02
Still pocket-sized
Folded, the Wide measures 2 × 4.7 × 1.2 in. and weighs 1.8 oz3 — two-thirds the weight of a C-A-T® Gen 7 at 2.7 oz.7 Snakestaff puts the ETQ at about 65% smaller than a standard windlass tourniquet.4
-
03
Power Curve™ band slot
The slot the band pulls through is curved rather than straight, to spread the load across the band and center the tension; with a straight slot, Snakestaff says, the band runs tighter at its edges than in its middle.3
-
04
Tri-Grip Windlass™
Three flat faces per side instead of a round rod, for finger purchase when hands and gloves are slick — textured short of the point where it tears nitrile gloves, in a high-strength polymer composite.3
-
05
Power Ring™
A steel ring under the windlass lifts it clear of the carabiner and gives mechanical advantage on the first one or two turns, the hardest turns on any windlass tourniquet.3
-
06
A backed band and a bigger lock
The Gen 2 band is backed with webbing so it stays rigid, will not fold onto itself and is easier to lasso around a limb — which matters more on a 1.5 in. band. The longer body keeps the band straight, and the enlarged carabiner seats the rod after many turns.3
-
07
Pull the band tight before you turn
Snakestaff traces the only negative first-generation reviews it has seen to users who did not tighten the band first, or did not reset the tourniquet after repeated use.3 In a 60-cadet manikin study, failed applications carried about three times the slack of successful ones.9
-
08
No chemlight on Gen 2
The first-generation ETQ Wide carried a chemlight. Snakestaff dropped it because it broke and activated in the mail and in pockets, and put the savings into more robust materials at the same price.3
-
09
Blue means trainer
The Blue ETQ Wide is Snakestaff's designated 1.5 in. trainer, so you practice without cycling the tourniquet you carry.3,4 The lifetime warranty covers manufacturing defects and excludes repeated use as a trainer.5
-
10
One casualty, one tourniquet
An ETQ that has been used on a casualty is single use. Do not clean it and return it to a kit — replace it.4
-
11
The Wide in the real-world record
Snakestaff's living record lists 18 reported real-world uses of the ETQ platform through 31 August 2026, with no reported product failures; the Wide appears in five — among them a pocket-carried Wide applied above a tourniquet already in place and held through a riverbank extraction, and a Wide carried in a holster and applied to a deputy shot during an arrest.6 These are manufacturer-collected reports, not a clinical study.
-
12
Registered, listed and made in the USA
Snakestaff Systems (South Salt Lake, Utah) is an FDA-registered device manufacturer, and the ETQ is listed as a Class I nonpneumatic tourniquet (product code GAX, 21 CFR 878.5900) — the 510(k)-exempt class every non-pneumatic limb tourniquet sits in.10 The Gen 2 features are patent pending.3
How to apply the ETQ Wide
Snakestaff's sequence for the ETQ, inside the placement rules taught in TCCC and TECC.
-
1Choose the placement. Under threat, or when you cannot find the source: high and tight — as high on the limb as possible, over clothing, after emptying the pockets under the band. When it is safe and you can see the wound: bare skin, 2–3 in. above it. Never across or directly over a joint; if that spot lands on the knee or elbow, go above the joint.1,4
-
2Route the band. Wrap the band around the limb, or slide the loop over it, and thread it back through the body with the rod facing you.4
-
3Pull the band tight first. Pull the free end as tight as you physically can and fasten it — you should not be able to slide a finger under it. The windlass finishes the job; it cannot make up for slack.4,9
-
4Pull up, then twist. Lift the rod and turn it, in either direction, until the bleeding stops and the distal pulse is gone. It will hurt. Keep turning until both endpoints are met.1,4
-
5Lock it. Seat the rod in the carabiner lock, and lock the remaining band in the gate the same way.4
-
6Record the time. Write the application time on the band or the casualty's skin — "TQ 1330" — and tell the receiving team.1,4
-
7Reassess. If bleeding continues or the distal pulse returns, tighten further or apply a second tourniquet side-by-side with the first.1 Pressure under any strap tourniquet can drop within minutes as muscles relax.8
-
8Leave it on, or convert if you are trained to. For a civilian, and especially after self-aid, leaving it on for the receiving clinicians is good practice. Under TCCC, a tourniquet is converted to a hemostatic or pressure dressing as soon as possible — with every effort to do it within 2 hours — when the casualty is not in shock, the wound can be watched closely and it is not an amputation.1
Where it fits
- Life-threatening bleeding from an arm or leg
- Any traumatic amputation, even one that is barely bleeding
- Everyday carry on the body — pocket, ankle, belt or plate carrier — and a staged unit in the vehicle, range bag or go bag
- A second tourniquet alongside the one already in your kit
- The neck, armpit or groin crease — those wounds are packed and pressed, not tourniqueted; the chest and abdomen are never packed
- Placement across or directly over a joint
- Minor bleeding that direct pressure or a pressure dressing controls
- Practice — use the Blue ETQ Wide trainer and keep the carry unit untouched
The evidence
What has been reported for the ETQ, and the independent studies that frame it.
| Study | Evidence type | What was studied | What it found |
|---|---|---|---|
| Snakestaff Systems, real-world use record v3.1, 2026 | Clinical · manufacturer case log | 18 reported non-training uses of the ETQ platform, 2023–2026, five involving the ETQ Wide; civilian, law-enforcement and EMS appliers | 17 worked as expected, no reported product failures, one unreadable source; no comparison group |
| Walters et al., Prehosp Emerg Care 2005 | Human volunteer | Seven commercial tourniquets self-applied to the thigh (n = 18) and the best four to the arm (n = 12), Doppler endpoint; the ETQ did not exist yet | Three were 100% effective on both limbs; others failed from too little mechanical advantage, breakage or intolerable pain |
| Katsnelson et al., Mil Med 2020 | Manikin · randomized | C-A-T® Gen 7, SAM® XT and SOFTT-W applied by 60 military-medicine cadets to a HapMed leg trainer | Slack predicted failure: 3.2 mm in successful vs 10.5 mm in failed applications |
| McCarty et al., JAMA Surg 2019 | Manikin · randomized crossover | 102 laypeople trained on the C-A-T® then applied five tourniquet types | 92.2% correct with the C-A-T® they trained on, 68.6% with the SOF®TT, 11.8% with elastic designs — skills did not fully transfer |
| Goralnick et al., JAMA Surg 2018 | Simulation · randomized trial | 465 laypeople at a stadium, simulated tourniquet scenario, four instruction arms | 16% correct with no training vs 88% after a one-hour course; 54.5% still correct 3–9 months later |
Strongest to weakest: human-volunteer studies, then simulation and manikin studies, then manufacturer reports. The four independent studies tested other tourniquets; they are listed for what they show about mechanical advantage, slack and training, which apply to the ETQ Wide as to any windlass tourniquet — and the 2005 volunteer study is the reason independent testing matters at all.11 Snakestaff states it has run human-subject testing of the ETQ and ETQ Wide with Doppler and ultrasound confirmation of arterial occlusion and is working with universities on independent trials.3
How it compares
The two Snakestaff widths, and the full-size windlass tourniquet most buyers weigh them against.
| ETQ Gen 2 Wide | ETQ Gen 2 Regular | C-A-T® Gen 7 | |
|---|---|---|---|
| Tightening | Windlass rod, Tri-Grip Windlass™ with Power Ring™ | Windlass rod, Tri-Grip Windlass™ with Power Ring™ | Windlass rod over a free-moving internal band |
| Band width | 1.5 in. constricting band | 1 in. | 1.5 in. strap |
| Windlass lock | Carabiner lock | Carabiner lock | Windlass clip plus a windlass strap |
| Weight | 1.8 oz | 1.4 oz | 2.7 oz |
| Folded size | 2 × 4.7 × 1.2 in. | 1.8 × 4.7 × 1.2 in. | Open length 37.5 in. |
| Trainer | Blue ETQ trainer, 1.5 in. | Blue ETQ trainer, 1 in. | Blue C-A-T® Gen 7 trainer |
| evidence-based standard | No | No | Yes — NSN 6515-01-521-7976 |
ETQ figures from Snakestaff; C-A-T® figures from North American Rescue.3,7 Absence from the evidence-based list does not by itself mean a device was tested and failed — Snakestaff notes the current ETQ Wide was developed after the last comprehensive evidence-based tourniquet review.2,3
Build the system
The carriers made for the ETQ, a ready-built kit around it, full-size tourniquets, and the rest of the bleeding-control kit.
Questions buyers ask
Package & specifications
Available Options:
- Grey
- Blue
- Orange
| Specification | Value |
|---|---|
| Width | 1.00 or 1.5 Inches Wide |
| Length | 37.5 Inches Long |
| Dimensions | 35% Smaller Than Other Tourniquets |
Domestic & Military Shipping
Free Standard Shipping: Automatically applied at checkout on all orders $200 and above within the 48 contiguous United States (CONUS).
APO/FPO Military Addresses: Unconditionally free standard shipping on every order, with no minimum purchase required.
Order Processing & Tracking
Fulfillment Timeline: In stock merchandise ships within 48-72 hours from Florida HQ.
Automated carrier tracking details are emailed immediately upon shipment dispatch.
30-Day Returns & Medical Safety
Returns: Unused, unopened equipment in original manufacturer packaging is eligible for return within 30 days of delivery.
Bio-Safety Notice: To ensure sterility and patient safety, medical consumables with opened or broken tamper-evident seals cannot be returned.
Return Facility: MED-TAC International Corp., 15757 Pines Blvd, Suite 154, Pembroke Pines, FL 33027.
Export Compliance
North American Rescue (NAR) products and rifle hard armor plates are strictly restricted to US and APO/FPO addresses and cannot be exported internationally.